1. The oscillating base comes factory set to oscillate at 45 degrees total angle. The oscillating
angle can be adjusted to 34 degrees of total angle (2 hole ATA equivalent) by moving the
linkage bar to the optional 34 degree oscillation hole.
2. To help in moving linkage, remove drive belt by slipping it down and off the large pulley.
3. Loosen lock nut by turning counter clockwise until it touches bottom of linkage bar.
4. Loosen top flange nut by turning counterclockwise until it touches bottom of lock nut.
5. Turn linkage bar bolt counter clockwise with a pliers or short arm hex wrench until linkage
bar bolt clears bottom plate of oscillating base.
6. Slide linkage bar bolt to the optional 34 degree hole.
7. Turn linkage bar bolt clockwise into bottom plate tapped hole until flange nut touches
bottom plate, then turn linkage bolt counter clockwise 1 turn.
8. Tighten top flange nut by turning clockwise until tight against bottom plate (hold linkage bar
bolt to prevent from turning).
9. Tighten lock nut by turning clockwise until tight against flange nut.
10. Attach drive belt by sliding it up and onto large pulley.