Eaton EAFR-101 User Manual

Eaton EAFR-101 User Manual

Arc point sensor relay
Hide thumbs Also See for EAFR-101:

Advertisement

Quick Links

MN026004EN
EAFR-101 Arc Point Sensor Relay User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Eaton EAFR-101

  • Page 1 MN026004EN EAFR-101 Arc Point Sensor Relay User Manual...
  • Page 2 CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other- wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or...
  • Page 3: Table Of Contents

    2.1 EAFR-101 Features ........
  • Page 4 13. ORDERING CODES ..........24 EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 5: Introduction

    – Millisecond The EAFR-101 can be used as a stand-alone relay or as part – Medium voltage of a more complex arc protection system through the binary bus.
  • Page 6 T1,T3,T4 Light Light + Current Light S2/S3/S4 T2,T4 S1 BO1 BI2 BI1 EAFR-101D S4 + S3 + S2 + 13 14 EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com Pantone Coated Background = Black Text = White...
  • Page 7: Simplified Block Diagram

    2. General 2.2 Simplified Block Diagram The EAFR-101 simplified block diagram (see Figure 3) shows the main components of the EAFR-101 relay. Figure 3. EAFR-101 Simplified Block Diagram. SW 6 LATCH SW 6 T2 / CBFP LATCH LATCH Power Error...
  • Page 8: Operation And Configuration

    Check the binary input wiring. BI2 - Amber Normal status. Binary input 2 activated. Binary input 2 has loose connection. Check the binary input wiring. BO1 - Amber Normal status. Binary Output activated. EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 9: Push-Button Description

    Non Latch Latch 150 ms 100 ms Configuration Select: EAFR-101D Dipswitch SW1 Configuration Select: 150 ms 100 ms Non Latch Latch Light and Current S1: Light Light and Current Light EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 10 Refer to Sections 3.5.10 and 6. Refer to Sections 3.5.1 and 6. Configuration Select otee: Section 3.5.1 shows EAFR-101 internal logic and dipswitch selections. For input and output, descriptions refer to chapter 6. Figure 5. EAFR-101 Configuration Selection 0. EAFR-101 Configuration 0 logic diagram SW1/7 &...
  • Page 11 & SW1/8 150ms SW1/5 100ms 150ms Setting EAFR101 Light / Light and Current S1: Light / Light and Current Latch / Non Latch 100 / 150 ms Configuration Select EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 12: Non-Volatile Memory

    Figure 8. EAFR-01 Point Sensor Mounted to the Compartment Wall. 4. Arc Sensors The EAFR-101 relay series provides the use of point arc light sensors to be utilized in different switchgear types, accord- ing to the specific application requirements. Arc light point sensors are typically installed in metal clad compartments, providing quick accurate location of the faulted area.
  • Page 13: Sensor Type Dependencies

    Table 7. Arc Sensor Dependencies. EAFR-01 EAFR-06 EAFR-07 EAFR-08 Connect the other end of the cable to a sensor channel EAFR-101 on the EAFR-101 or EAFR-110P relay (see Figure 12). EAFR-102 EAFR-110P EAFR-110F EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 14 Error LED should be reset and then close both end Figure 14). side-covers of the point sensors (see Figure 17). Figure 14. EAFR-01 Sensor Connection - Step 5. EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 15: System Self-Supervision

    (see Figure 18). 6. Application Examples Figure 18. EAFR-01 Sensor Connection Step 9. The EAFR-101 may be applied to a variety of power switch- gear and control gear layouts and technologies. Some typi- cal applications are described in this section. Please consult your nearest Eaton representative for a solution to your particular application.
  • Page 16 T1 / T2 T1,T3,T4 Light + Current Light S1 Chan Light + Current Light S2/S3/S4 T2,T4 S1 BO1 BI2 BI1 EAFR-101D S4 + S3 + S2 + 13 14 EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 17: Wind Power Application Example (Light Only Condition)

    6.2 Wind Power Application Example (Light Only Condition) sors. In this application, three sensor channels with three The EAFR-101 may be applied using arc light only as the sensors in each channel are utilized. In the event of arc light tripping criteria.
  • Page 18 6. Application Examples Figure 20. Typical Wind Power Applications by EAFR-101 and EAFR-101D (Continued). Eaton Arc Flash Relay Configuration POWER Select ERROR CBFP Time Non Latch Latch T1 / T2 T1,T3,T4 Light + Current Light S1 Chan Light + Current...
  • Page 19: Circuit Breaker Failure Protection (Cbfp)

    The breaker failure function is activated if the EAFR-101 detects the presence of light after a set operating time. When EAFR-101 is set to operate on light and current, EAFR-101 both parameters must persist to activate CBFP . Breaker fail- ure can be set to operate either on 100 ms or 150 ms delay (Section 3.5: Dipswitch Settings).
  • Page 20: Inputs

    EAFR-101D 7 . Connections Figure 20. EAFR-101 Terminals at Rear Plate and EAFR-101D Connections. (Continued). Eaton Arc Flash Relay Configuration POWER Select ERROR CBFP Time Non Latch Latch T1 / T2 Light + Current S1 Chan T1,T3,T4 Light Light + Current...
  • Page 21: Wiring Diagram

    Station battery EAFR101 T2 / CBFP Light / Light and Current S1: Light / Light and Current Latch / Non Latch 100 / 150 ms Configuration Select +24V TRIP Alarm EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 22: Dimensions And Installation

    19 in. (482.6 mm) rack (height of 4U and 1/8 of a unit wide). Figure 23. EAFR-101 Dimensions in Millimeters (In.) (Side View). 175 (6.89) 160 (6.30) 10 (0.39) (0.67) 157 (6.18) (1.50) 10 (0.39) EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 23 9. Dimensions and Installation Figure 23 EAFR-101 and EAFR-101D (Dimensions in mm [in.]) - Side View (Continued). 145 (5.71) 110 (4.33) 34 (1.34) 108 (4.25) EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 24: Testing

    Steps 4 and 5. 10. Press the SET push-button to reset all indications and latches. 11. Repeat the testing procedure for all sensors. EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 25: Carrying Out Testing In Light And Current Mode

    ON. The EAFR-101 operation time test is not required at com- missioning as it is performed by Eaton as a type test and Verify the relay output(s) activation(s) by checking the routine production test. Refer to the routine test reports...
  • Page 26: Test Plan Example

    Section 3.5 of this operate even if sensor is manual activated. 12.2 Auxiliary Voltage Vaux (110-220) Vac / (125-250) Vdc ±20% Maximum Interruption 100 ms Maximum Power Consumption Standby Current 90 mA EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 27: Trip Relays T1, T2, T3, And T4

    = 80 ... 1,000 MHz 10 V/m (According. to EN 61000-4-3, Class III) - Conducted RF Field (According. to f = 150 kHz ... 80 MHz 10 V EN 61000-4-6, Class III) EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 28: Ordering Codes

    Arc light glass fiber sensor (High Temperature) - 40 m (131.23 ft) EAFR-08-45 65C2015G08 Arc light glass fiber sensor (High Temperature) - 45 m (147.64 ft) EAFR-08-50 65C2015G09 Arc light glass fiber sensor (High Temperature) - 50 m (164.05 ft) EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 29 13. Ordering Codes Notes: EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 30 13. Ordering Codes Notes: EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 31 13. Ordering Codes Notes: EAFR-101 Arc Point Sensor Relay User Manual MN026004EN February 2016 www.eaton.com...
  • Page 32 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2016 Eaton All Rights Reserved Eaton is a registered trademark. Printed in USA Publication No. MN026004EN / TBG1261 All trademarks are property February 2016 of their respective owners.

Table of Contents