Section 6: Testing The System; 6-1: Testing The System Before Gas Connection; 6-2: Testing The System With Gas Connection (Highly Recommended) - Montigo R Series Installation & Maintenance Manual

Ndoor gas fireplace natural gas or propane gas
Table of Contents

Advertisement

Section 6: Testing the system

6-1: Testing the system before gas
connection
The Control and Power Vent System can be safely tested prior to finish
framing the Fireplace. This test can be done quickly and efficiently to
ensure all systems function according to the design specifications.
The fireplace should be installed on the rough-in frame, Figure 3 with
the Power Vent Module and the Vent run connected.
• The control panel is supplied with a power cord plug in.
• Plug it into an extension cord or any other 110 Volt power supply.
• If the red LED is illuminated (beside the fuse) you have power to
the panel.
• If no LED, check fuse and replace with equally rated fuse.
• Turn the wall switch to the on position.
• Wall switch and combustion air LED illuminate approximately 30
seconds after the power vent reaches factory set speed. The flue
gas switch LED will light up approximately 1 minute after flue gas
LED is lit and the gas valve will turn on. You can hear a clicking sound
and the Hot Surface Ignitor will glow red. This confirms the control
system operation. Note: If the flue gas LED does not light up after
1 minute, slowly increase the power vent speed until the LED turns
on. Speed controller located inside the control box, see figure 8.d.
6-2: Testing the system with gas
connection (Highly recommended)
The Control and Power Vent System can be safely tested prior to finish
framing the Fireplace. This test can be done quickly and efficiently to
ensure all systems function according to the design specifications.
The fireplace should be installed on the rough-in frame, Figure 3 with
the Power Vent Module and the Vent run connected.
• Turn gas supply valve on
• The control panel is supplied with a power cord plug in.
• Plug it into a extension cord or any other 110 Volt power supply.
• If the red LED is illuminated (beside the fuse) you have power to
the panel.
• If no LED, check fuse and replace with equally rated fuse.
• Turn the wall switch to the on position.
• Once the fireplace is running normally, confirm manifold pressure
and supply pressure
XG0225 - 170223
Installation
Figure 9.c LED Indicators
21

Advertisement

Table of Contents
loading

Table of Contents