Temperature test
▷ A temperature test is required on diaphragm gas
meters with temperature conversion BK..Te only.
▷ The accuracy of the temperature measurement
can be verified with this test.
▷ The temperature test can only be carried out in
Service mode.
CAUTION
To avoid damage to the unit:
Comply with ambient temperature, see
page  15 (Technical data). Deviations from
the permitted ambient temperature will be re-
corded in the error memory.
▷ Temperature measurement accuracy, see
page  15 (Technical data).
 Install the diaphragm gas meter in a climatic
chamber.
 Activate Service mode – see page 5 (Service
mode).
 Change to the "Temperature" menu.
▷ The current gas temperature is displayed.
4 Close the climatic chamber.
5 Select an ambient temperature as a reference
value and bring the climatic chamber to this tem-
perature.
▷ To ensure there is also a uniform temperature
in the meter, we recommend starting the meter
air/gas flow during the temperature adjustment
phase.
▷ Ensure that temperature distribution remains
uniform and stable during the temperature
measurement.
6 Compare the measured value to the temperature
reference value.
▷ If required, several reference values can be
checked. In this case, repeat the test as of
point  5 .
Assistance in the event of
malfunction
? Fault
! Cause
• Remedy
Possible faults and suggested solutions
? The
symbol is displayed.
! If the
symbol appears next to a measured
value, this means that the value is invalid.
• After the next data synchronization, the data are
recorded again correctly and
? When pressing the user keys, the backlight-
ing and/or display remain switched off. A
beep can nevertheless be heard.
! Energy-saving mode is active. Due to excessive
use of the index, the average energy consump-
tion has been exceeded.
• Leave the index unused for an extended period,
? When pressing the user keys, the display
! The index is defective.
• Contact the manufacturer.
? The
! Low battery. This symbol is only displayed when
• Replace the battery.
▷ In the case of faults which are not described here,

Spare parts

Battery
For meters without communication module:
Elster Part No.: 32906520.
For meters with communication module:
Elster Part No.: 72910321.
Communication module
Use ATEX compliant communication modules only.
A safety sticker with the following code must be
attached to the communication module:
Electrical connection parameters, see page  15
(Technical data).
Screw locking cap
Elster Part No.: 32447510.
disappears.
GB-14
e.g. 24 hours. After this, the user interface will
once again be available.
remains switched off and no beep can be
heard.
symbol is displayed.
battery power is low.
contact the manufacturer immediately.
II 3G Ex ic IIA Gc (-25°C ≤ Ta ≤ +55°C).