WARNING
For the safety of both the operator and service personnel, care should be taken when
using this centrifuge if handling substances that are known to be toxic, radioactive or
contaminated with pathogenic microorganisms. When Risk Group II materials are used (as
identified in the World Health Organization "Laboratory Bio-Safety Manual"), a Bio-Seal
should be employed. In the event that materials of a higher risk group are being used,
more than one level of protection must be provided. The use of flammable or explosive
materials as well as those materials which have a vigorous chemical reaction is prohibited.

Model Description

The Horizon Model 755VES, Premier, features the largest
holding capacity of Drucker's Performance Series centrifuges.
Its standard horizontal rotor and carriers can accommodate up
to 24 test tubes. The 755VES offers control over almost every
aspect of the unit's operation from variable acceleration and
deceleration to easy time and speed input. High speed and
force capability produces platelet-poor/free plasma and greatly
reduces processing times. The exclusive Drucker horizontal
rotor allows for quick and easy sample loading and complete
horizontal separation. Save settings in one of 10 memory
locations and recall them at the touch of a button.
Intended Use
This centrifuge is an IVD accessory, and therefore subject to the former EU IVD Directive
98/79/EC and the current EU IVD Regulation 2017/746. It is a laboratory product
designed to separate components by generation of relative centrifugal force. It separates
human and animal samples – such as blood, urine and other body fluids -- collected in
appropriate specimen receptacles, either alone or with reagents or other additives. As
a general purpose laboratory centrifuge, it is designed to also run other containers filled
with chemicals (non-flammable, non-explosive, non-volatile, and non-highly reactive
only), environmental samples, and other non-human body samples. This centrifuge
should be operated by trained personnel only. Any use other than those intended by
the Manufacturer is explicitly prohibited. [Maximum sample density is 1.15 grams/mL].
Supplied Accessories (Standard)
See next page for optional rotor/accessories
One (1) 6-Carrier
Six (6) 4-Place Carriers*
Horizontal Rotor*
p/n 7786015
Also included (not shown):
• One (1) 10´ Line Cord
• One (1) Operator's Manual
• Twenty-Four (24) 0.25
Cushions for Glass Tubes
˝
See the next page for a description of optional accessories.
Drucker Diagnostics warranties that this centrifuge is free from
defects in workmanship and parts for 2 years.
Six (6) Carrier Cap*
p/n 7713023
p/n 7713035
WARRANTY:
*The rotor and rotor accessories are
rated for a rotational speed of 3800
RPM (a force of 2560 xg).