Model Description; Supplied Equipment; Warranty Information - Horizon Fitness 853VES Operator's Manual

Laboratory centrifuge
Table of Contents

Advertisement

WARNING
For the safety of both the operator and service personnel, care should be taken when
handling substances that are known to be toxic, radioactive or contaminated with
pathogenic microorganisms when using this centrifuge. When Risk Group II materials
are used (as identified in the World Health Organization "Laboratory Bio-Safety Manual"),
a Bio-Seal should be employed. More than one level of protection must be provided in
the case of materials of a higher risk group. The use of flammable or explosive materials
as well as those materials which chemically react vigorously is prohibited.

Model Description

The Horizon Model 853VES, is a medium capacity centrifuge
with unmatchedperformance. The 853VES offers control over
almost every aspect of the unit's operation from variable
acceleration and deceleration to easy time and speed input.
Save settings in one of 10 memory locations and recall them at
the touch of a button. High speed and force capability produces
platelet-poor/free plasma and greatly reduces processing
times. The exclusive Drucker horizontal rotor allows for quick
and easy sample loading and complete horizontal separation.
Intended Use
This centrifuge is an IVD accessory, and therefore subject to the
former EU IVD Directive 98/79/EC and the current EU IVD Regulation 2017/746. It is a
laboratory product designed to separate components by generation of relative centrifugal
force. It separates human and animal samples – such as blood, urine and other body
fluids -- collected in appropriate specimen receptacles, either alone or with reagents or
other additives. As a general purpose laboratory centrifuge, it is designed to also run
other containers filled with chemicals (non-flammable, non-explosive, non-volatile, and
non-highly reactive only), environmental samples, and other non-human body samples.
This centrifuge should be operated by trained personnel only. Any use other than those
intended by the Manufacturer is explicitly prohibited. [Maximum sample density is 1.15
grams/mL].
Supplied Accessories (Standard)
See next page for optional rotor/accessories
One (1) 12-Place
Horizontal Rotor
7786024*
Also included (not shown):
• One (1) 10´ Line Cord
• One (1) Operator's Manual
See the next page for a description of optional accessories.
Drucker Diagnostics warranties that this centrifuge is free from
defects in workmanship and parts for 2 years.
Twelve (12) 75 mm Carriers
7713079*
WARRANTY:
*The rotor and rotor
accessories are rated
for a rotational speed
of 5000 RPM.
03

Advertisement

Table of Contents
loading

Table of Contents