CHANGES OF MODE AND POWER SUPPLY - Page 2 - OF THE HYDRINS 2 AND ITS DISPLAY Sommaire HYDRINS 2 : CHANGE OF MODE (WITH OR WITHOUT DISPLAY) ....3 I.1 ) Tools ................................3 I.2 ) Disassembling ............................3 I.3 )
CHANGES OF MODE AND POWER SUPPLY - Page 3 - OF THE HYDRINS 2 AND ITS DISPLAY HydrINS 2 : change of MODE (with or without display) I.1 ) Tools • 1 flat screwdriver. • 1 Allen key of 4 I.2 ) Disassembling...
Page 4
CHANGES OF MODE AND POWER SUPPLY - Page 4 - OF THE HYDRINS 2 AND ITS DISPLAY • Remove the stainless steel head and the batteries. Be careful not to tear off the wires and identify the battery 1 and the battery 2 as it is indicated on the battery support (Cf.
CHANGES OF MODE AND POWER SUPPLY - Page 5 - OF THE HYDRINS 2 AND ITS DISPLAY I.3 ) Change of MODE The change of mode determining the use or not of the display, please respect the configuration of the probe (switch and batteries) as described below.
CHANGES OF MODE AND POWER SUPPLY - Page 6 - OF THE HYDRINS 2 AND ITS DISPLAY I.4 ) Reassembling • Reassemble the batteries support with its three screws and be careful not to pinch the wires (Cf. Picture 3) •...
CHANGES OF MODE AND POWER SUPPLY - Page 7 - OF THE HYDRINS 2 AND ITS DISPLAY II.1 ) External power supply with internal connection (6-28V) II.1.a ) Configuration of switches SW1, SW2 et SW3 Put SW1 in position : ALKALINE...
Page 8
CHANGES OF MODE AND POWER SUPPLY - Page 8 - OF THE HYDRINS 2 AND ITS DISPLAY • You can now pass the electric cable on the cable gland provided for this purpose and to connect your source on the « + » and « - » connector block POWER « 6V to 28V »...
CHANGES OF MODE AND POWER SUPPLY - Page 9 - OF THE HYDRINS 2 AND ITS DISPLAY II.2 ) External power supply with the military connector (6-28V) II.2.a ) Configuration of switches SW1, SW2 et SW3 Put SW1 in position...
CHANGES OF MODE AND POWER SUPPLY - Page 10 - OF THE HYDRINS 2 AND ITS DISPLAY III ) Display : External power supply to lithium batteries Opposite procedure of what we have just seen, so it is necessary to disconnect the external power supply, to change the position of the switches (see below) and to connect the lithium pack.
CHANGES OF MODE AND POWER SUPPLY - Page 11 - OF THE HYDRINS 2 AND ITS DISPLAY IV ) Display : External power supply for 4-20 mA output to lithium batteries for pulse output Same process that previously. However, some connectors must be moved in order to disable the 4-20 mA function.
CHANGES OF MODE AND POWER SUPPLY - Page 12 - OF THE HYDRINS 2 AND ITS DISPLAY Picture 15 • Disconnect the connector J2 of the 4-20mA board and connect it on the motherboard J4 connector. Keep J1 disconnected (Cf. Picture 16).