Read Operatioin - General Measure GM8802F-2 User Manual

Field mounting transmitter
Table of Contents

Advertisement

R
VR
C
ZY
C
ZN
C
GY
C
GN
O
CZ
O
EN/DI
O
RB
O
RS
5.2.1.2 Read operation
1. Read state and weight from single channel
Read command:
STX
Address
Correct response:
STX
Address
Here:
STX
—— 1bit,start character:02H
Address —— 2bits,range from 01~16(30H 31H~31H 36H)
Channel no. —— 1bit,31H:channel no.1;32H:channel no. 2
R
—— 1bit,52H
W
—— 1bit,57H
State
—— 2bits
High
byte
D7
D6
Fixed
Fixed
None
40H
Weight —— 6bits,not including sign. Return"space space O F L space" when weight
overflow;Return"space space E R R space" when AD error;Return "space space
O F F space"when AD shut.
CRC
—— 2bits,check sum
CL
—— 1bit,carriage return:0DH
LF
—— 1bit,line feed:0AH
14
Transmitter mode
Zero calibration
with weights
Zero calibration
without weights
Gain calibration
with weights
Gain calibration
without weights
Zeroing
operation
Start/shut AD
operation
Restart system
operation
Reset operation
Channel no.
Channel no.
R
D5
0:AD
0: AD shut
normal
1
1: AD start
1:AD
error
GM8802F-2 Field Mounting Transmitter
Return transmitter mode: 02F2
channel no. must be A)
The channel no. must be A
The channel no. must be A
R
W
T
W
T
State
Weight
Low byte
D4
D3
0:
positive
1:
minus
CRC
CR
LF
CRC
CR
D2
D1
0:
0:
normal
nonzero
1:
1:zero
overflow
GM8802-F2110101
(The
LF
D0
0:
unstable
1: stable

Hide quick links: