Operation - Wayne CWS Series Operating Instructions And Parts Manual

Table of Contents

Advertisement

ELECTRICAL
Risk of electrical shock. This pump is designed
for indoor installation only, unless housed and protected from the
elements.
Installer un écran autour du tuyau d'entrée pour
éviter de piéger des nageurs, des animaux et des débris.
Select the proper size wire and fuse. Time delay fuses are recommended
over standard fuses for motor circuit protection. All pump motors have
built-in automatic overload protection that will prevent damage to the
motor due to overheating. If wire run is a short distance, a cord/plug
assembly may be used as long as it meets the minimum wire gage size
called out in Chart 2.
TO AIR VOLUME CONTROL
JET ASSEMBLY
Figure 8 - Shallow Well Jet
Do not connect to electric power supply until
unit is permanently grounded. Connect ground wire to approved ground
then connect terminal provided.
Ne pas connecter à l'alimentation électrique
tant que l'unité n'est pas mise à la terre en permanence. Brancher le fil
de mise à la terre à la masse approuvée puis raccorder la borne fournie.
A metal underground water pipe or well casing at least 10 feet long
makes the best ground electrode. If plastic pipe or insulated fittings
are used, run a wire directly to the metal well casing or use a ground
electrode furnished by the power company.
There is only one proper ground terminal on the unit. The terminal is
located under the pressure switch cover, is painted green and is identified
as GRD. The ground connection must be made at this terminal (Figure 9).
The ground conductor must not be smaller than the circuit conductors
supplying the motor.
The voltage of power supply must match the voltage of the pump.
The unit has dual voltage motors preset at the factory to 115 volts. The
motors can be converted to 230 volts by changing the voltage selector to
the desired voltage (Figure 10). Disconnect power, use needle nose pliers
to pull the selector out approximately 1/4 in., point too, and then reinsert
in correct position.
Disconnect power and release all pressure from
the system before attempting to install, service, relocate or perform any
maintenance.
Débrancher de la source d'alimentation puis
dissiper toute la pression du système avant d'essayer d'installer, de
réparer, de déplacer ou de procéder à l'entretien.

OPERATION

PRIMING THE SHALLOW WELL PUMP
To prevent damage to the pump, do not start
motor until pump has been filled with water.
Pour éviter d'endommager la pompe, ne pas
démarrer le moteur tant que la pompe n'a pas été remplie d'eau.
When the deep well pump is used with the bolt-
on shallow well jet, be sure the control valve slot (Figure 11) is in the
vertical (open) position at all times.
1.
Remove prime plug.
2.
Fill pump and piping completely full of water.
3.
Replace the prime plug.
CHART 2 - RECOMMENDED FUSE AND WIRING
DATA - 60 HZ MOTORS
Dual
Element
Fuse
HP
Volt
250V
115
20
1/2
230
10
115
20
3/4
230
10
115
20
1
230
10
* above is the suggested size only. Check with local or state code for
proper sizing.
9
CWS Series
Distance in Feet
From Meter to Motor
0
51
101
to
to
to
50
100
200
Wire Size
14
12
10
14
14
14
14
12
8
14
14
14
14
12
8
14
14
14
www.waynepumps.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cws100Cws50Cws75

Table of Contents