Deep well pumps must be mounted to either a pre-charged, conventional type, or free standing pressure tank. A Wayne jet assembly is required (not included) for This product can expose you to chemicals, including DEHP, operation of this pump.
Page 3
CWS Series Disconnect power and release all pressure from All wiring should be performed by a licensed or the system before attempting to install, service, relocate or perform any certified electrician. maintenance. Lock the power disconnect in the open (off) position. Tag Tout câblage doit être réalisé...
Operating Instructions and Parts Manual INSTALLATION PRE-INSTALLATION LOCATION WATER SUPPLIES Select a location as close to the water supply as possible. Be sure to The water supplies illustrated in Figure 16 (on page 13) are possible comply with any state or local codes regarding the placement of the sources for water.
CWS Series DRIVEN WELL (FIGURE 16, PAGE 13) INSTALLATION (CONTINUED) • Drive the point several feet below the water table. PRESSURE SWITCH NOTE: A packer type foot valve can be installed in the well (Figure 2, The pressure switch provides for automatic operation. The pump starts Illustration B).
Page 6
Operating Instructions and Parts Manual DEEP WELL INSTALLATION INSTALLATION (CONTINUED) DRILLED WELL (4 IN. OR LARGER) WITH TWO PIPE JET (FIGURE 16, ON PAGE 13 AND FIGURE 3, BELOW) TO PUMP Assemble a 1-1/4 in. foot valve (not included) to the jet body. A 1-1/4 in.
Page 7
CWS Series DEEP WELL PUMP WITH HORIZONTAL AND VERTICAL INSTALLATION (CONTINUED) STORAGE TANK (FIGURES 5 AND 6) Install the air volume control on the tank as shown. Slope the horizontal pipes upward toward the pump to prevent trapping air. If horizontal distance exceeds 25 feet, see Chart 1 for recommended pipe sizes.
Page 8
Operating Instructions and Parts Manual CONVERTING THE DEEP WELL PUMP TO SHALLOW WELL INSTALLATION (CONTINUED) OPERATION (FIGURE 8) For shallow wells (25 feet or less), a bolt-on shallow well jet is available as an accessory for deep well pumps. The jet attaches to the front of the AIR VOLUME CONTROL pump with the two bolts provided and converts the deep well pump into a shallow well pump.
CWS Series ELECTRICAL Disconnect power and release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Risk of electrical shock. This pump is designed for indoor installation only, unless housed and protected from the Débrancher de la source d’alimentation puis...
Page 10
Operating Instructions and Parts Manual PRIMING THE DEEP WELL PUMP OPERATION (CONTINUED) To prevent damage to the pump, do not start GROUND motor until pump has been filled with water. LINE SCREW Pour éviter d’endommager la pompe, ne pas démarrer le moteur tant que la pompe n’a pas été remplie d’eau. Remove prime plug.
CWS Series WATERLOGGED TANKS: PRE-CHARGED MAINTENANCE If a pre-charged tank becomes waterlogged, the bladder is normally Disconnect power and release all pressure from leaking or broken. the system before attempting to install, service, relocate or perform any maintenance. Lock the power disconnect in the Test the tank by depressing the air valve.
Page 12
Operating Instructions and Parts Manual NOTES 10. Remove the shaft seal from the impeller, make sure the stainless steel sleeve comes off the impeller, all you should see on the back of the impeller is the brass colored threaded insert (Figure 13). 11.
Page 13
Operating Instructions and Parts Manual CWS Series www.waynepumps.com...
Operating Instructions and Parts Manual TROUBLE SHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump will not run 1. Power off 1. Turn power on or call power com pa ny 2. Blown fuse or tripped breaker 2. Replace fuse or reset circuit break er 3.
Page 15
Operating Instructions and Parts Manual CWS Series For Replacement Parts or Customer Support, Call 1-800-237-0987 Please provide following information: Address parts correspondence to: - Model number Wayne Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
LIMITED WARRANTY For three years for CWS Series models from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser, any part or parts of its Well Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.
Need help?
Do you have a question about the CWS Series and is the answer not in the manual?
Questions and answers