5 - Operation

Engaging the turbine fan

When you are going to work with a spray gun, or just need agitation in
the main tank, the fan can be disengaged by the lever.
The lever is located behind the pump. When the lever (A) is in the centre
position, the fan is disengaged.
μ
ATTENTION! The PTO, pump and fan must stand completely still,
before the fan is engaged or disengaged.
μ
ATTENTION! To avoid shock loading the fan transmission, the
tractor engine must run idle before engaging the PTO.

Nozzles

The standard nozzle can be closed individually by turning them 90º.
When open the direction can be adjusted within a range of +/- 15º.
A non-drip valve (A) is fitted to avoid chemical spillage the sections are
shut off.
The nozzle type (B) are a hollow cone nozzle, also known as ATR. They
are colour-coded and the working range is 5-15 bar.
This type of nozzle can also be used with hydro-pneumatic equipment.
μ
ATTENTION! It is not advisable to exceed 15 bar with ATR nozzles
as the droplets would be too small, and the liquid will either
evaporate under hot conditions or be lost due to wind drift.