  • Page 1 User Guide...
  • Page 2 Smart Combustible Gas Sensor Thanks for using Aztech Kyla product If you need support or help, please visit www.kyla.aztech.com...
  • Page 3: Product Description

    Product Description The Smart Combustible Gas Sensor is used for detecting combustible gas leakage, Reset Button preventing any possible Testing Button danger. Status Indicator The sensor adopts extra Gas Convection Holes low-power consumption Zigbee wireless module. LED States a. Solid Green Light with No Alarm Sound: Power On b.
  • Page 4: Installation Tips

    Installation Tips CEILING Sensor 0.3m - 1.0m Diameter 0.3m - 1.0m FLOOR Gas Stove Note: Before installation, please confirm the detecting gas density - if heavier or lighter than air. If detected gas is heavier than air (LPG, etc.), install at 0.3-1m height from the floor.
  • Page 5 Operation Guide Step 1: Download Aztech Kyla App from Google Play/App Store Aztech Kyla App Step 2: Login to Aztech Kyla App, then add “Smart Combustible Gas Sensor” to device list to enable the device.
  • Page 6 Step 3: 3.1 Ad-Hoc Network Insert the Smart Combustible Gas Sensor into power socket and enter Ad Hoc network condition. App will be prompted once succesfully connected to the network.
  • Page 7 b.) Once the detector is on, the power indicator will show green and the buzzer will beep once, signalling that the device is on warm-up state. Then, will be followed by red LED and yellow LED alternately flashing. Flashing will stop after 3 mins when detector has entered normal working status.
  • Page 8 Step 3: 3.2 Manual Network After warming up, keep pressing the reset key for 2 sec until green LED flashes quickly. App will be prompted once connected succesfully. Green indicator will turn off after 3 sec and will start lighting normally once detector has entered normal working status.
  • Page 9: Technical Speci Cations

    Technical Speci cations Product Dimensions: 79 x 68 x 31mm Alarm Sound: 75dB/m Alarm Sensitivity: 6% LEL ± 3% LEL Networking: Zigbee Ad-hoc Operating Temperature: -10~50°C Working Humidity: Max 95% RH Wireless Networking Distance: ≤ 100m (Open Area)
  • Page 10 Notes 1. Shell surface will be slightly hot on normal working conditions. 2. Please dismantle detector while decorating house. 3. Avoid spraying aerosol around sensor. 4. Oil adhesion on gas convection window may affect the sensitivity of gas detector after prolonged usage. Cleaning the gas convection window every 3 months (or based on specific oil pollution level) with a brush mixed with a little amount of detergent is recommended.
  • Page 11: Troubleshooting

    Emergency Alarm Response The detector will keep alarming while the natural gas level or LPG density in air has exceeded the normal range. Please do the following after: 1. Shut down the tube valve right away. 2. Extinguish all fire sources and do not use anything that is a fire hazard (e.g lighters, matches, etc.).