O: SENSOR button
P: ACL button
(ALL CLEAR)
Q: DISPLAY
NOTE
• The wireless remote controller sends the temperature signal to the air conditioner regularly at three
minute intervals. If the signal from the wireless remote controller stops for more than ten minutes
due to the loss of the wireless remote controller or other trouble, the air conditioner will switch to the
temperature sensor which is built into the indoor unit and control the room temperature. In these
cases, the temperature around the wireless remote controller may differ from the temperature
detected at the air conditioner's position.
How to set the ADDRESS (
Setting addresses of indoor units for remote controller
1. Press the ADDRESS button for
2. By each pressing the ADDRESS
3. Press the SET button.
NOTE
• If the set address on the remote controller matches with the controller address in an indoor unit, the
buzzer will beep.
Address indication
on the remote
controller
Setting of the
If the remote
address switch of
controller indicates
the controller in an
"ALL":
indoor unit
Match this address with
the address indicated
You can set any
on the remote
controller.
address in the
controller.
NOTE
SWITCH
OI-404-02 - 11EG
Remote Control Unit (continued)
Use this button to switch to the temperature sensor of the remote
controller.
The temperature sensor of the air-conditioner is selected at the factory
and the display indicates
If the remote controller is located near a heat source, such as a space
NOTE
heater or in direct sunlight, press the SENSOR button to switch to the
sensor on the indoor unit.
Puts the wireless remote controller into pre-operation status. Always
press this button after replacing the batteries.
Information on the operating conditions is displayed while the wireless
remote controller is switched on. If the unit is turned off, only the mode
that was set previously is still displayed.
)
Operation
more than four seconds.
button, the indicated address will
change from "ALL" to "1" through "6"
in turn and lap to "ALL". Adjust the
address switch of an indoor unit you
want to operate to match its address
with the address indicated on the
remote controller.
If the remote
controller indicates
"1":
• To set the address to 1, 2, or 3, switch this "SWITCH" knob to the left; to set
the address to 4, 5, or 6, switch this "SWITCH" knob to the right.
under this selection.
Indication
The display of the remote
$
controller indicates
and the current address
appears and blinks.
$
The indicated address
stops blinking and remains
for five seconds.
If the remote
If the remote
controller indicates
controller indicates
"2":
"6":
,
2
2 - 11