Hot-Plug Scsi Hard Drive Leds - Compaq ProLiant BL20p Maintenance And Service Manual

Hide thumbs Also See for ProLiant BL20p:
Table of Contents

Advertisement

Connectors, LEDs, and Switches
Table 4-5: Hot-Plug SCSI Hard Drive LEDs
1 Activity
Off
Off
Off
On or
flashing
4-8
COMPAQ CONFIDENTIAL Codename: AvalancheX Part Number: 316080-001 Last Saved On: 12/18/02 11:38 AM
2 Online
3 Fault
Off
Off
Off
On
On
Off
On
Off
Compaq ProLiant BL20p Server Blade Maintenance and Service Guide
continued
Means
OK to replace the drive online if a predictive failure
alert is received (refer to the following section for
details) and the drive is attached to an array controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
OK to replace the drive online.
The drive has failed and has been placed off-line.
OK to replace the drive online if a predictive failure
alert is received (refer to the following section for
details), provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and configured as part of an array.
OK to replace the drive online if a predictive failure
alert is received (refer to the following section for
details), provided that the array is configured for fault
tolerance and all other drives in the array are online.
The drive is online and being accessed.