Connections and controls........................25 Operating..............................30 7.1 Starting the device........................... 30 7.2 Main menu............................30 7.3 Menu overview..........................33 7.4 Functions in 1-channel DMX mode................... 34 7.5 Functions in 2-channel DMX mode................... 34 LED Theater Spot 100 3000K LED spotlight...
Page 4
Table of contents Technical specifications........................35 Plug and connection assignments....................37 Troubleshooting............................38 Cleaning............................... 40 Protecting the environment......................41 LED Theater Spot 100 3000K LED spotlight...
Page 5
LED Theater Spot 100 3000K LED spotlight...
If you sell the unit please make sure that the buyer also receives this manual. Our products are subject to a process of continuous development. Thus, they are subject to change. LED Theater Spot 100 3000K LED spotlight...
Our online guides provide detailed information on technical basics Online guides and terms. Personal consultation For personal consultation please contact our technical hotline. If you have any problems with the device the customer service will Service gladly assist you. LED Theater Spot 100 3000K LED spotlight...
Texts and values displayed on the device are marked by quotation marks and italics. Examples: ‘24ch’ , ‘OFF’ . 1.3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual. LED Theater Spot 100 3000K LED spotlight...
Page 9
This combination of symbol and signal word indicates a pos- sible dangerous situation that can result in material and environmental damage if it is not avoided. Warning signs Type of danger Warning – high-voltage. Warning – suspended load. LED Theater Spot 100 3000K LED spotlight...
Page 10
General notes Warning signs Type of danger Warning – danger zone. LED Theater Spot 100 3000K LED spotlight...
Extend the life of the device by regular breaks in operation and avoid switching it on and off frequently. This device is not suitable for continuous use. LED Theater Spot 100 3000K LED spotlight...
Page 12
Within the device there are areas where high voltages may be present. Never remove any covers. There are no user-serviceable parts inside. Do not use the device if covers, protectors or optical components are missing or damaged. LED Theater Spot 100 3000K LED spotlight...
Page 13
Eye damage caused by high light intensity Never look directly into the light source. WARNING! Risk of epileptic shock Strobe lighting can trigger seizures in photosensitive epilepsy. Sensitive persons should avoid looking at strobe lights. LED Theater Spot 100 3000K LED spotlight...
Page 14
NOTICE! Risk of fire Do not block areas of ventilation. Do not install the device near any direct heat source. Keep the device away from naked flames. LED Theater Spot 100 3000K LED spotlight...
Page 15
Failure to do so could result in damage to the device and possibly injure the user. Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire. LED Theater Spot 100 3000K LED spotlight...
Operation in stand-alone or DMX mode (one or two channels, depending on operating mode) Operating via buttons and display on the unit Very quiet temperature-controlled fan for quiet operation Ideally suitable for use in theatres LED Theater Spot 100 3000K LED spotlight...
Page 17
For technological reasons, the light output of LEDs decreases over their lifetime. This effect increases with higher operating temperature. You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightness. LED Theater Spot 100 3000K LED spotlight...
Secure the barn door with a safety cable on the spotlight after installation. The safety cable must run outside the barn door and must not interfere with the light emission. LED Theater Spot 100 3000K LED spotlight...
Page 19
When mounting the device onto a stand, ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand. LED Theater Spot 100 3000K LED spotlight...
Page 20
Always work from a stable platform whenever installing, moving or servicing the unit. In doing so, the area underneath the unit must be cordoned off. The safety cable must be attached to the bracket. LED Theater Spot 100 3000K LED spotlight...
Page 21
Installation Please note that this device must not be connected to a dimmer. LED Theater Spot 100 3000K LED spotlight...
Starting up Starting up Create all connections while the device is off. Use the shortest possible high-quality cables for all connections. Take care when running the cables to prevent tripping hazards. LED Theater Spot 100 3000K LED spotlight...
Page 23
Connect the output of the first DMX device to the input of the second one, and so on to form a daisy chain. Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor (110 Ω, ¼ W). LED Theater Spot 100 3000K LED spotlight...
Page 24
Connect the DMX output of the master device to the DMX input of the first slave device. Then connect the DMX output of the first slave device to the DMX input of the second slave device and so on. LED Theater Spot 100 3000K LED spotlight...
Connections and controls Connections and controls LED Theater Spot 100 3000K LED spotlight...
Page 26
Calls up the main menu or a submenu. 2 Power-Twist connector for the power supply of the device. 3 Power-Twist connector for the voltage supply of a further device. 4 [DMX IN] DMX input. 5 [DMX OUT] DMX output LED Theater Spot 100 3000K LED spotlight...
Page 27
6 Focus control. Adjusts the beam angle in a range from 15° to 45°. 7 Fuse holder. Should the fuse have blown, disconnect the unit from the power supply and replace the fuse with a new fuse of the same type. LED Theater Spot 100 3000K LED spotlight...
Page 28
Connections and controls LED Theater Spot 100 3000K LED spotlight...
Page 29
Connections and controls 8 Mounting bracket. 9 Front side with barn door attachment. 10 Locking screw for the mounting bracket. LED Theater Spot 100 3000K LED spotlight...
[Enter] to enter the respective submenu or confirm a new value. To return to the previous menu level without changes, press [Menu]. If you do not press any button for 60 seconds, the display will automatically turn off. Possible changes are not applied. LED Theater Spot 100 3000K LED spotlight...
Page 31
Press [Menu]. Press [Up] or [Down] repeatedly until the display shows ‘tEmP’ and confirm with [Enter]. The display shows the current internal temperature of the device in ‘XX’ format (numeric value). With [Menu] to return to the parent menu. LED Theater Spot 100 3000K LED spotlight...
Page 32
Operating mode Slave Instead of using a DMX controller, connect the device to a master device using a suitable DMX cable. The device follows exactly the operation of the Master to which it is connected. LED Theater Spot 100 3000K LED spotlight...
Master dimmer (0 % to 100 %) 7.5 Functions in 2-channel DMX mode Channel Value Function 0 … 255 White light dimmer (0 % to 100 %) 0 … 255 Stroboscope effect (0 % to 100 %) LED Theater Spot 100 3000K LED spotlight...
115 W Protection IP20 Dimensions (W × H × D) 160 mm × 185 mm × 260 mm Fuse 5 mm × 20 mm, 3 A, 250 V, fast-acting Weight 5 kg LED Theater Spot 100 3000K LED spotlight...
Page 36
Technical specifications Environmental conditions Temperature range 0 °C…40 °C Relative humidity 50 %, non-condensing LED Theater Spot 100 3000K LED spotlight...
The unit offers a 3-pin XLR socket for DMX output and a 3-pin XLR plug for DMX input. Please refer to the drawing and table below for the pin assignment of a suitable XLR plug. Configuration Ground, shielding Signal inverted (DMX–, ‘cold signal’) Signal (DMX+, ‘hot signal’) LED Theater Spot 100 3000K LED spotlight...
Never connect the DMX input or output to audio devices such as mixers or ampli- fiers. In the following we list a few common problems that may occur during operation. We give you some suggestions for easy troubleshooting: LED Theater Spot 100 3000K LED spotlight...
Page 39
DMX interface circuits. If the procedures recommended above do not succeed, please contact our Service Center. You can find the contact information at www.thomann.de. LED Theater Spot 100 3000K LED spotlight...
The fan grids of the device must be cleaned on a regular basis to remove dust and dirt. Before cleaning, switch off the device and disconnect AC-powered devices from the mains. Use a lint- free damp cloth for cleaning. Never use solvents or alcohol for cleaning. LED Theater Spot 100 3000K LED spotlight...
Dispose of this device through an approved waste disposal firm or through your local waste facility. When discarding the device, comply with the rules and regulations that apply in your country. If in doubt, consult your local waste disposal facility. LED Theater Spot 100 3000K LED spotlight...
Page 42
Notes LED Theater Spot 100 3000K LED spotlight...
Need help?
Do you have a question about the LED Theater Spot 100 3000K and is the answer not in the manual?
Questions and answers