Varytec 650 Antihalo User Manual

Theatre spotlight

Advertisement

650/1000 Antihalo
650/1000 Fresnel
650/1000 PC
300/500 Antihalo
300/500 Fresnel
theatre spotlight

Advertisement

Table of Contents
loading

Summary of Contents for Varytec 650 Antihalo

  • Page 1 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight...
  • Page 2 Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 28.12.2017, ID: 335412, 335413, 335424, 335427, 390866, ...
  • Page 3: Table Of Contents

    Table of contents Table of contents General information..........................5 1.1 Further information........................... 6 1.2 Notational conventions........................7 1.3 Symbols and signal words....................... 7 Safety instructions..........................10 Features............................... 15 Connections and controls........................16 Maintenance.............................. 18 5.1 Installing / replacing the illuminant..................18 5.2 Changing the lens..........................
  • Page 4 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight...
  • Page 5: General Information

    General information General information This manual contains important instructions for the safe operation of the unit. Read and follow the safety instructions and all other instructions. Keep the manual for future reference. Make sure that it is available to all those using the device. If you sell the unit please make sure that the buyer also receives this manual.
  • Page 6: Further Information

    General information 1.1 Further information On our website (www.thomann.de) you will find lots of further information and details on the following points: Download This manual is also available as PDF file for you to download. Use the search function in the electronic version to find the topics of Keyword search interest for you quickly.
  • Page 7: Notational Conventions

    General information 1.2 Notational conventions This manual uses the following notational conventions: Instructions The individual steps of an instruction are numbered consecutively. The result of a step is indented and highlighted by an arrow. Example: Switch on the device. Press [Auto]. ð...
  • Page 8 General information Signal word Meaning DANGER! This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided. WARNING! This combination of symbol and signal word indicates a pos- sible dangerous situation that can result in death or serious injury if it is not avoided.
  • Page 9 General information Warning signs Type of danger Warning – danger zone. 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight...
  • Page 10: Safety Instructions

    Safety instructions Safety instructions Intended use This device is intended to be used as an illumination effect. The device is designed for profes- sional use and is not suitable for use in households. Use the device only as described in this user manual.
  • Page 11 Safety instructions Safety DANGER! Danger for children Ensure that plastic bags, packaging, etc. are disposed of properly and are not within reach of babies and young children. Choking hazard! Ensure that children do not detach any small parts (e.g. knobs or the like) from the unit.
  • Page 12 Safety instructions DANGER! Electric shock caused by high voltages inside Within the device there are areas where high voltages may be present. Completely disconnect the device from the power supply before you open or remove covers. Mount all covers and attach them firmly before connecting the device again.
  • Page 13 Safety instructions WARNING! Eye damage caused by high light intensity Never look directly into the light source. WARNING! Risk of burns at the surface and inside of the device The surface and the inner parts of the device can become very hot during opera- tion.
  • Page 14 Safety instructions NOTICE! Operating conditions This device has been designed for indoor use only. To prevent damage, never expose the device to any liquid or moisture. Avoid direct sunlight, heavy dirt, and strong vibrations. NOTICE! Power supply Before connecting the device, ensure that the input voltage (AC outlet) matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker.
  • Page 15: Features

    Features Features Professional theatre spotlight for almost any application, for example in clubs, bars, small stages and theatres. Special features of the devices: Model 650/1000 Antihalo, model 650/1000 Fresnel and model 650/1000 PC are suitable for halogen stage lights with GX9.5 base, 230 V, maximum power consumption 1000 W (not included) Model 300/500 Antihalo and model 300/500 Fresnel are suitable for halogen stage lights with GY9.5 base, 230 V, maximum power consumption 500 W (not included)
  • Page 16: Connections And Controls

    Connections and controls Connections and controls Rear panel 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight...
  • Page 17 Connections and controls 1 Mounting bracket for floor placement or hanging. 2 Safety cable eyelet. 3 Locking screw for the mounting bracket. 4 Power cord. 5 Locking screw for focus. Loosen the screw and position the slider for optimum illumination. 6 Retaining bracket 7 Holder for barn doors, colour films or filters.
  • Page 18: Maintenance

    Maintenance Maintenance 5.1 Installing / replacing the illuminant DANGER! Electric shock caused by high voltages inside Within the device there are areas where high voltages may be present. Completely disconnect the device from the power supply before you open or remove covers.
  • Page 19 Maintenance WARNING! Risk of burns at the surface and inside of the device The surface and the inner parts of the device can become very hot during opera- tion. After switching off the device wait for at least 15 minutes before you start any maintenance activities.
  • Page 20 Maintenance NOTICE! Possible damages due to wrong type of lamp Any attempt to use the device with a lamp other than those specified in this manual can result in severe damages to the device. Only use a lamp of the specified type. 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight...
  • Page 21 Maintenance Notes on the illuminant Only the following illuminants are permitted: Model Base Power consumption Theater Spot 650/1000 Antihalo Base GX9.5 650 W 1000 W Theater Spot 650/1000 Fresnel Base GX9.5 650 W 1000 W Theater Spot 650/1000 PC Base GX9.5 650 W 1000 W Theater Spot 300/500 Antihalo...
  • Page 22 Maintenance Procedure Make sure that the device is turned off, disconnected from the mains and completely cooled down. Move the device in a horizontal position. Carefully unscrew the star knob screw on the rear panel completely. Slide the upper housing cover all the way back. Carefully pull the old illuminant out of the socket on the bottom of the unit.
  • Page 23: Changing The Lens

    Maintenance 5.2 Changing the lens DANGER! Electric shock caused by high voltages inside Within the device there are areas where high voltages may be present. Completely disconnect the device from the power supply before you open or remove covers. Mount all covers and attach them firmly before connecting the device again.
  • Page 24 Maintenance WARNING! Risk of burns at the surface and inside of the device The surface and the inner parts of the device can become very hot during opera- tion. After switching off the device wait for at least 15 minutes before you start any maintenance activities.
  • Page 25 Maintenance Reattach the retaining ring in its original position and tighten the knurled screw. Check the lens for firm fit. Slide the upper housing cover all the way to the front. Tighten the star knob screw completely. Check that the upper housing cover is properly seated. 650/1000 Antihalo 650/1000 Fresnel 650/1000 PC 300/500 Antihalo 300/500 Fresnel theatre spotlight...
  • Page 26: Technical Specifications

    Technical specifications Technical specifications 650/1000 Fresnel/Antihalo Illuminant Halogen stage light with base GX9.5, 230 V Power consumption 650 W Power consumption 1000 W Lens diameter 150 mm Mains plug e. g. item no. 324015 Barn door e. g. item no. 335429 Zoom range 10°...
  • Page 27 Technical specifications 650/1000 PC Illuminant Halogen stage light with base GX9.5, 230 V Power consumption 650 W Power consumption 1000 W Lens diameter 150 mm Mains plug e. g. item no. 324015 Barn door e. g. item no. 335429 Zoom range 10°...
  • Page 28 Technical specifications 300/500 Antihalo/Fresnel Illuminant Halogen stage light with base GY9.5, 230 V Maximum power consumption 300 W Maximum power consumption 500 W Lens diameter 120 mm Mains plug e. g. item no. 324015 Barn door e. g. item no. 335419 Zoom range 10°...
  • Page 29: Cleaning

    Cleaning Cleaning Optical lenses Clean the optical lenses, that are accessible from the outside, regularly in order to optimize the light output. The frequency of cleaning depends on the operating environment: wet, smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device.
  • Page 30: Protecting The Environment

    Protecting the environment Protecting the environment Disposal of the packaging mate- rial For the transport and protective packaging, environmentally friendly materials have been chosen that can be supplied to normal recycling. Ensure that plastic bags, packaging, etc. are properly disposed of. Do not just dispose of these materials with your normal household waste, but make sure that they are collected for recycling.
  • Page 32 Musikhaus Thomann · Hans-Thomann-Straße 1 · 96138 Burgebrach · Germany · www.thomann.de...

Table of Contents