Chase Inlet - Pacific energy FP30 Arch Craftsman Installation Instructions Manual

Surround for fp30ar b series wood fireplace
Table of Contents

Advertisement

Figure 7: FP30 Installed 3.
Dimensions to note when installing the non-combustible wall board
A
Non-combustible wall board and all decorative facing materials.
B
Minimum height from base of the fireplace covered by non-combustible wall
board
C
Minimum width of non-combustible wall board covering front of unit.
D
Supplied steel stud wall section.
E
Combustible stud framing.
F
Chase air intake - locate on front between unit and chase side wall if the chase
front is flush with wall. (see Figurue 5 for distance from opening).
F
Chase air intake - Can be located on the side, back or underneath the chase,
as long as that inlet is drawing air from inside the house.
When the Craftsman Arched Front is installed on a FP 30 AR Series B Fireplace, the chase requires
[100cm2]
of chase inlet air. This air helps support the fireplace's convection airflow and is separate from the
Combustion Intake air. The duct doesn't have to be round or a single inlet. The requirement is that the total
inlet area must be equal to 16sq.in. or greater.
This air must enter the chase no higher than 12" [305mm] from the bottom of the fireplace. And can be placed
on the front (off to the side of the unit (Figure 6 on page 7) or on the sides or back of the chase if it pro-
trudes into the room. Air can be drawn from under the chace if that space is sealed within the house enve-
lope. The air must come from inside the house, preferably the room the fireplace is installed in.
FP30 Arch Craftsman 240417-16
D
A
B
C

CHASE INLET

E
F
8
84" (2.135m)
60"(1.525m
Min. 16 sq." (100 cm2)
Min. 16 sq." (100 cm2)
16sq.in.
5055.5154-A