Installation Precautions; Storage Precautions; Label On The Coil Section(S) - EVAPCO ATC-E Operation And Maintenance Instruction Manual

Induced draft and forced draft closed circuit coolers and evaporative condensers
Table of Contents

Advertisement

Operation and Maintenance Instructions
WARNING: Sound reducing options are available . In case these options are not taken in consideration, the customer
must design the installation to comply with local sound requirements and legislation .
WARNING: In order to avoid excessive pressure, proper safety valves should be foreseen in the cooling installation .
These safety measures are not delivered by Evapco and are the responsibility of the customer/contractor .
The application of these safety measures has to be evaluated for the cooling system as a whole and not
limited to the partly completed machinery .
WARNING: Atmospheric corrosion and corrosion due to the use of corrosive media at the inside/or outside of the
coils is forbidden and voids the PED certification .
WARNING: Every handling that effects the integrity of the pressure vessel (example, but not limited to, welding,
grinding, drilling, . . . ) is forbidden and voids the PED certification .

Installation Precautions

WARNING: The coil connections are not designed to support piping . The water / glycol / refrigerant piping always
need to be supported (by others) . See also Bulletin 131-E "Piping Evaporative Condensers" .

Storage Precautions

WARNING: Never use plastic sheets or tarps to protect a unit during storage . This practice can trap heat inside the
unit and could potentially cause damage to plastic components .

Label on the coil section(s)

WARNING: Do not operate the pressure vessel at service conditions outside of the PED nameplate located
at the coil connection . See position 1 for the location of the PED nameplate .
WARNING: Maximum working temperature of the pressure vessel as mentioned on the PED nameplate exceeds
the nominal operating temperature of the unit . Never apply pressure vessel temperatures above 65°C
or consult the factory for approval .
WARNING: Legal periodic controls of the pressure vessel need to be performed according to the legal requirements
of the country .
2A
(2)
11A
FLUID IN
ENTREE DU FLUIDE
FLUESSIGKEIT EIN
ENTRATA FLUIDO
11A
34
EVAPCO
EUROPE N.V.
1
INDUSTRIETERREIN OOST 4010
B-3700 TONGEREN
BELGIUM
0036
YEAR
DWG.
MODEL
S.N.
VOLUME
FLUID
MAX WORKING PRESSURE
bar
DESIGN TEMPERATURE
-20°C / +140°C
WORKING
TEMPERATURE -10°C / +120°C
TEST
bar DATE
PRESSURE
12A
FLUID OUT
SORTIE DU FLUIDE
FLUESSIGKEIT AUS
USCITA FLUIDO
12A
1 .
PED NAMEPLATE/SERVICE CONDITIONS
2 .
EVAPCO LOGO (both sides)
2A .
RIGGING INSTRUCTIONS (both ends)
11A . FLUID IN
12A . FLUID OUT
17A . WARNING ELIMINATORS
34 .
WARNING PVC PIPE
35 .
DO NOT COVER ELIMINATORS
5
35
17A
2
(2)