Novatek-electro RS-485 Operating Manual page 17

Interface controller
Table of Contents

Advertisement

Range of
Parameter
values
IP-address of
IP-address
the server
Character
Server address
string
Protection
Specified
password for
Character
access to the
string
mode of setting
Parameter is
not used
The specified
password for
Character
recording per-
string
mission using
incoming SMS
The specified
password for
Character
reading per-
string
mission using
incoming SMS
The specified
password for
recording per-
Character
mission via
string
MODBUS TCP
in devices using
RS-485
The specified
password for
Character
reading
string
permission via
MODBUS TCP
Enable the
protection mode
0 – 1
against writing
via SMS
Enable the
protection mode
0 – 1
against reading
via SMS
Enable the
protection mode
0 – 1
against writing
via MODBUS
TCP
Enable the
protection mode
0 – 1
against reading
via MODBUS
TCP
Parameter is
not used
Table 5.8 Continued
NOVATEK-ELECTRO
Factory
setting
It is used when connecting to the server (except for mode
"2"), if the server address setting is turned off with text string.
0.0.0.0
IP address of the remote server with which the connection is
supported.
It is used when connecting to the server (except for mode "2"),
if the server address setting is turned on with text string.
modbus.
Address of the remote server with which the connection is
overvis.c
supported.
om
The string of up to 36 characters can be indicated as address.
This string should not have any spaces.
It is used to access the MODBUS TCP configuration mode.
11111
The string of 5 to 10 characters in length can be indicated as
password. This string should not have any spaces.
0
0
It is not used; it should be equal to 0 for compatibility.
It is used to verify the authenticity of incoming SMS with
request for record or with acknowledgment of the fault. The
gap
string of 3 to 10 characters in length can be indicated as
password. This string should not have any spaces.
It is used to verify the authenticity of incoming SMS with
request for reading or with acknowledgment of the fault. The
gap
string of 3 to 10 characters in length can be indicated as
password. This string should not have any spaces.
It is used to access devices connected to the EM-481, to
request write or control functions that can change the status
of these devices. The string to 10 characters in length can
be indicated as password. This string should not have any
spaces.
It is used to access devices connected to the
EM-481, to request read functions, or to access the EM-481
registers, except for registers of version, password, mode and
tabs. The string to 10 charac-ters in length can be indicated as
password. This string should not have any spaces.
0 – Protection against recording is regulated with help of
0
other parameters (password);
1 – Blocking of queries via SMS for function of writing.
0 - Protection against reading is regulated with help of other
0
parameters (password);
1 – Blocking of queries via SMS for function of reading.
0 – Protection against recording is regulated with help of
other parameters (password) or deactivated;
0
1 - Blocking of any queries for functions, excepting functions
of MODBUS 1, 2, 3, 4, 7, 17, 20.
0 – Protection against reading is regulated with help of other
parameters (password) or deactivated;
1 – Blocking of queries for functions of MODBUS 1, 2, 3, 4, 7,
0
17, 20, excepting reading using function 3 of registers of
version, mode and tabs.
0
0
It is not used; it should be equal to 0 for compatibility.
17
-
-
Description
Address
470 –
473
474 –
509
510 –
519
520 –
529
530 –
539
540 –
549
550 –
559
560 –
569
570
571
572
573
574
EM-481