Download Print this page
Campbell SR50AH Instruction Manual

Campbell SR50AH Instruction Manual

Sonic ranging sensor heater option
Hide thumbs Also See for SR50AH:

Advertisement

Quick Links

SR50AH
Sonic Ranging Sensor
Heater Option
Instruction Manual
Issued 26.8.08
©
Copyright
2008 Campbell Scientific (Canada) Corp.
Printed under licence by Campbell Scientific Ltd.
CSL 795

Advertisement

loading

Summary of Contents for Campbell SR50AH

  • Page 1 SR50AH Sonic Ranging Sensor Heater Option Instruction Manual Issued 26.8.08 © Copyright 2008 Campbell Scientific (Canada) Corp. Printed under licence by Campbell Scientific Ltd. CSL 795...
  • Page 3 Note that goods sent air freight are subject to Customs clearance fees which Campbell Scientific will charge to customers. In many cases, these charges are greater than the cost of the repair. Campbell Scientific Ltd,...
  • Page 5: Table Of Contents

    ® the Adobe Acrobat bookmarks tab for links to specific sections. 1. Heater Introduction ............. 1 2. Specifications .............. 1 3. Maintenance ..............2 Figures 1. SR50AH Heater option ................2 2. Complete transducer assembly with power connection ......4...
  • Page 7: Heater Introduction

    SR50A manual which should be referred to for general operating instructions. 1 Heater Introduction The heater option on the SR50AH is intended for installations where rime ice is problematic. The heater will help to prevent the ice from forming on the transducer, which can impair proper operation of the sensor.
  • Page 8: Maintenance

    The same maintenance procedures apply to the SR50AH as the regular SR50A sensor. Please refer to the SR50A manual for maintenance information. The transducer and desiccant replacement is slightly different for the SR50AH as it is for the SR50A. When ordering replacement transducers ensure that the SR50AH part# C2370 is ordered.
  • Page 9 Instruction Manual To replace the desiccant remove the desiccant holder plate with the Philips 4-40 screw. Cutting the tie strap will allow the old packets to be removed for replacement. During reassembly ensure that the desiccant does not come in contact with the metal backing of the transducer.
  • Page 10: Complete Transducer Assembly With Power Connection

    SR50AH Sonic Ranging Sensor Heater Option 1. Replace the transducer assembly and the second o-ring that seats under the transducer assembly. 2. Reassemble the sensor in the reverse order. Please observe the orientation of the parts, wiring and desiccant. Figure 2 Complete transducer assembly with power connection...
  • Page 12 CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za sales@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)