WEG ENC-02 Installation, Configuration & Operating Manual page 4

Table of Contents

Advertisement

Available languages

Available languages

To fix the encoder and prepare the connection cable of the electric signals, follow
the instructions of item 3.
For the correct installation of modules ENC-01 and ENC-02, follow the steps
below:
step 1: With the inverter de-energized, remove the front cover of the CFW11
(figure 2);
step 2: Carefully plug-in the module into slot 2 (figure 3(a));
step 3: Place and tighten the grounding screw and fixture of the module
(figure 3(b));
step 4: Set the module switches as shown in table 1;
step 5: Connect the encoder cables to connector XC4 of modules ENC-01 and
ENC-02.
2
a
Figure 2: Removal of front cover
a
Figure 3: Installation of optional module into slot
b
c
b