hager 4501 Installation Instructions Manual

4500 series; 4600 series; electric exit device

Advertisement

Quick Links

DEVICES COVERED IN THIS DOCUMENT:
LM – Latch Bolt Monitoring *
ELR – Electric Latch Retraction (not for use with Mortise Exit)*
RX – Request to Exit (Field Installation Kit 2-649-5001) *
ED – Electric Dogging *
EL or EU – Electrified Mortise Trim (ordered with 4501N Exit) *
MLR – Motorized Latch Retraction (Field Installation Kit 2-649-5007) *
* Quick Connects Optional
ELECTRICAL SPECIFICATIONS AND COLOR CODES FOR WIRES
For use with all Hager monitored exit device modifications.
Request to Exit (RX) switch monitors egress by push bar activation of the exit device.
Latch Bolt Monitoring (LM) switch monitors the latch mechanism of the exit device.
Authorized Ingress (AI) switch monitors ingress by trim or key retraction of the exit device latch.
Request to Exit (RX)
Electrical
SPDT Monitoring Switch
Specification
Maximum Contact Rating:
3 AMP @125VAC
2 AMP @ 30VDC
Color Code
Yellow Wire – Common
Red Wire – Normally Open
for wires
Grey Wire – Normally Closed
Wire Gauge – #22 AWG
WIRE ROUTING AND DOOR PREP INSTRUCTIONS
1. Follow exit device instructions and template to prepare door and frame for installation.
2. Door fabricator to provide a 3/8" ** diameter (minimum) raceway through door to allow insertion of
electrical wires running between exit device and power transfer device (electric hinge).
** Quick Connects Require 5/8" Raceway
**
Rev 8, Rev Date: 8/27/2018
Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com
4500/4600 Series Electric Exit Device
DE – Delayed Egress
AI – Authorized Ingress *
RX2 – Dual Request to Exit
ET – Electric Trim (4500 Series only)
OBDE-On-Board Delayed Egress
Latch Bolt Monitoring (LM)
SPDT Monitoring Switch
Maximum Contact Rating:
3 AMP @125VAC
2 AMP @ 30VDC
Black Wire – Common
White Wire – Normally Open
Red Wire – Normally Closed
Wire Gauge – #22 AWG
Door fabricator to provide a
3/8" ** diameter (minimum)
Raceway through door to
Allow insertion of electrical
Wires running between exit
Device and power transfer
27390025
Installation Instructions
Authorized Ingress (AI)
SPDT Monitoring Switch
Maximum Contact Rating:
3 AMP @125VAC
2 AMP @ 30VDC
Black Wire – Common
Orange Wire – Normally Open
Purple Wire – Normally Closed
Wire Gauge – #22 AWG
device
I-ED00367
Page 1 of 3

Advertisement

loading

Summary of Contents for hager 4501

  • Page 1 3/8” ** diameter (minimum) Raceway through door to Allow insertion of electrical Wires running between exit Device and power transfer device Rev 8, Rev Date: 8/27/2018 27390025 Page 1 of 3 Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com...
  • Page 2 4. The ELR, MLR, DE and ED all occupy the same space in the push bar. None of these can be done in conjunction with each other or with cylinder dogging or any Alarm Kit functions. Rev 8, Rev Date: 8/27/2018 27390025 Page 2 of 3 Hager Companies 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 www.hagerco.com...
  • Page 3 Quick connects are installed on the wires from the exit device electrification options. These quick connects are compatible with Hager Quick Connect Harness Cable which can be used to plug into Hager hinges with quick connects to provide quick and accurate wiring of the door.

This manual is also suitable for:

4601