Basic Operating Instructions; Rate, Time, And Counter Modes Explained; Visual Reference; How To Change A Parameter's Value (The Short Story) - DART Controls DM8000 CONTROL SERIES Instruction Manual

Field programmable digital tachometer for rate, time, and count
Table of Contents

Advertisement

Rate, Time, and Counter Modes Explained

In Rate Mode, the DM8000 measures the input frequency, converts it to the user-defi ned units, and
displays the rate in the display window of the user interface. Most applications utilize rate mode and
display in units such as gallons-per-minute, feet-per-second, and RPM.
In Time Mode, the DM8000 measures the input frequency, converts it to the user-defi ned time units,
and displays the time in the display window. This mode is most-commonly used in time-sensitive
processes such as conveyor ovens and plating applications.
In Counter Modes, the DM8000 counts each incoming pulse, scales it per the user-defi ned ratios,
and displays the count in the display window. Typical counting applications include linear material
measurement, cycle counters, and liquid volume measurement.
In Rate or Time with Direction modes a quadrature pick-up is required. In these modes it will perform
the same functions as above under Rate or Time modes but the FWD and REV annunciators will be
used to indicate the direction that the pick-up is turning. Please refer to the FORWARD / REVERSE -
TIMING CHARTS for more information on the timing of the quadrature pick-up.
In Dual Rate or Dual Time modes two signals are needed, one on S1 and one on S2. In these modes
it will perform the same functions as above under Rate or Time modes but the S1 and S2 annunciators
will be used to indicate which signal is being viewed. In order to switch between the two signals the
Up and Down buttons are used; Down for S1 and Up for S2.

Visual Reference

CONTROLS
Display Window

How to Change a Parameter's Value (The Short Story)

1. Hold down the Enter button until Parameter-Selection Mode is entered
2. Using the Up and Down buttons, select the desired parameter number to view or edit
3. Press the Enter button to change the value of the parameter
4. Using the Up and Down buttons, change the parameter's value as desired
5. Press the Enter button to permanently save the changes (Return to Parameter-Selection Mode)
6. Select parameter zero and press the Enter button to return to Running Mode

Operating the User Interface (The Long Story)

Although the DM8000 user interface is very versatile, it is also simple to setup and operate. With just
a few button presses, it allows the user to confi gure a number of adjustable parameters. The LED
display has three basic operating modes: Running Mode, Parameter-Selection Mode, and Value Mode.
Each of the three modes have specifi c visual indicators that allow the user to immediately determine
the current state or mode of the user interface. Parameter-Selection Mode and Value Mode can only
be entered if the Program Enable jumper is in the "On" position.

Basic Operating Instructions

Page
Ite
Valu
FWD
REV
S1
m
TACHOMETER
Tach
S2
ENTER
7
ENTER (Select) Button
Up & Down Buttons

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DM8000 CONTROL SERIES and is the answer not in the manual?

Questions and answers

Related Products for DART Controls DM8000 CONTROL SERIES

Table of Contents