Parameter 95 – Factory Default Command
When set to a value of 5, the unit will be reset to factory default settings. This can also be
achieved by applying power to the unit with both the Enter and Down buttons depressed. The
programming jumper must be in the "On" position for this method to function.
Parameter 98 – Save to User Default Area Command
When set to a value of 5, the unit will store all adjustable parameters to the user default area.
The user default area is intended to be a location where an OEM or integrator can store settings
specifi c to their application. Using this, an OEM can easily refresh their custom settings in the
fi eld if an end-user accidentally reconfi gures the unit unsuccessfully. Another common use for
this area is testing and initial setup. The user can store known-good settings here and easily
experiment without the fear of losing the optimal confi guration.
Parameter 99 – Restore from User Default Area Command
When set to a value of 1, the unit will restore the all adjustable parameters from the user default
area. See parameter 98 for additional information.