17) From the tee on the drain hose, blow out the drain valve using compressed air or carbon
dioxide.
18) Move the service switch to the "CIRC." position and the control switch to the "OFF"
position.
19) Turn off the power supply.
20) Reconnect the thermistor connector to the control board K3 (white) connector.
Reconnect the water pump connector.
21) Close the inlet water supply line drain valve.
22) Remove all ice from the dispenser unit/storage bin and clean the dispenser unit/storage
bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
23) Replace all removed parts and panels in their correct positions.
Harvest Water Valve Hose
Drain Hose Tee
Suction Hose
Fig. 4
53
Harvest Water Valve
Wash Valve
Fill/Refill Water Valve Hose
Fill/Refill Water Valve
Float Switch Flush Tube
Drain Valve