Download Print this page

Panduit T568B Installation Instructions page 4

Shielded modular plug

Advertisement

© Panduit Corp. 2017
4
Pin #
T568A BRN
1.00"
(Cable end 1)
5
(Cable end 2)
Verify
load bar
orientation
1
8
Pins
6
8
Drain wire
Collar barbs
1
Pins
8
1
Pins
8
9
Plug
housing
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
INSTALLATION INSTRUCTIONS
8
7
6
5
4
3
BRN/
BLU/
ORG/
ORG WHT
BLU WHT
WHT
(Cable end 1)
1
8
Pins
7
(Cable end 1)
(Cable end 2)
Collar latches
Strain collar
guides
(Cable end 1)
Collar locking
tabs
MPT5-8AS
10
• Straighten and align untwisted conductors using a circular
motion while holding conductors in respective divider slots.
• Maintain grip of conductors in T568A wiring scheme.
• Trim conductors on an angle approximately 1.00" from
divider leading edge.
2
1
GRN/
GRN WHT
• Orient load bar with contact slots facing downward.
• Guide conductors into load bar holes while holding
conductors in the divider.
• Slide load bar towards divider until flush.
• Ensure the divider/load bar is centered and perpendicular to
the cable axis.
• Trim conductors flush with load bar face.
• Hold the load bar and divider stationary while sliding the strain
relief collar forward until there is no gap between the collar
and divider.
• Ensure the drain wire is routed through the strain collar
guides.
• Confirm the cable jacket extends beyond the collar barbs.
Boot position
• Align pin #1 of cable sub-assembly (cable, load bar, divider,
when using
and strain relief collar) with pin #1 of plug housing.
CSPT
• Grip the strain relief collar and insert cable sub-assembly into
the plug housing. (Fig. 9)
• Push sub-assembly into housing until collar locking tabs
engage the plug housing pocket. Although not required, TX6
PLUS Plug Assembly Tool (CSPT) is available to facilitate this
step.
• Use tool MPT5-8AS to complete plug termination. (Fig. 10)
• Trim or press excess drain wire between the collar latches.
• Push up boot and engage with collar latches.
• Visually check plug. Assembly is complete.