Download Print this page
CDI Meters 5400 Manual

CDI Meters 5400 Manual

Flowmeter for compressed-air systems

Advertisement

Quick Links

CDI 5400
FLOWMETER FOR COMPRESSED-AIR SYSTEMS - Rev. 3
• Easy to install
• Display rotates to facilitate use on horizontal
or vertical pipes
• No moving parts
• Weather resistant and surge protected
• Milliamp output
• Pulse output convertible to threshold output
• User-configurable scaling, filtering and units
of measure
• Optional wired and wireless outputs for networking
The CDI 5400 clamps onto a pipe, with two flow-sensing probes
projecting into the pipe through 3/16-in. drilled holes. It seals
directly to the pipe; no cutting or welding is required for installa-
tion. Because each flowmeter is made and calibrated for a
specific size of pipe, the digital display indicates flow directly,
with no setup or adjustment.
The meter measures flow by maintaining one probe warmer
than the other. It determines the mass flow rate from the amount
of heat required. The flow rate, in scfm or equivalent units, is
shown on a large, four-digit display; a 4-20 mA output and a
pulse output permit remote dis-play, totalizing and data collection.
AVAILABLE SIZES
Nominal
Range
b
Size
(scfm)
a
2 in.
600
2.5 in.
800
3 in.
1200
4 in.
2000
5 in.
2500
6 in.
5000
8 in
6000
(a) Other sizes are available. Please contact CDI. For metering larger
pipe sizes, please see our 5400 Series flowmeters.
(b) Range of milliamp output and recommended maximum flow. Flowmeters
for copper pipe have smaller ranges. Meters will function at somewhat
higher flow rates but at reduced accuracy.
CDI METERS, INC.
Find Quality Products Online at:
Model No. for
Model No. for
Sch 40 Steel
Type L Copper
5400-20S
5400-20C
5400-25S
5400-25C
5400-30S
5400-30C
b
5400-40S
5400-40C
5400-50S
5400-60S
5400-80S
Specifications are subject to change without notice.
GlobalTestSupply
www.
SPECIFICATIONS
Accuracy
5 percent of reading plus 1 percent of range for flows from
10 percent to 100 percent of indicated range at air tempera-
tures between 20 and 120 degrees Fahrenheit
Fluids
Compressed Air, Nitrogen
Operating Pressure
200 psig maximum on Sch. 40 steel and on Type L Copper;
consult CDI for other materials and higher pressures.
Input Power
250 mA at 24 Vdc
Output resistance
600 Ohms max.
Exposed Materials
Stainless steel, gold, thermal epoxy and Viton (seal)
Display
Four-digit LED display
Response time
One second to 63 percent of change in value at flows above
30 percent of range
US Patent 6,802,217
.com
10/24/2016
© CDI Meters, Inc. 2016
sales@GlobalTestSupply.com

Advertisement

loading

Summary of Contents for CDI Meters 5400

  • Page 1 • Optional wired and wireless outputs for networking SPECIFICATIONS The CDI 5400 clamps onto a pipe, with two flow-sensing probes projecting into the pipe through 3/16-in. drilled holes. It seals Accuracy directly to the pipe; no cutting or welding is required for installa- 5 percent of reading plus 1 percent of range for flows from tion.
  • Page 2 (CDI where the meter will be mounted and allow the pres-sure to 5400-XX-DG). For the two- and 2-1/2 inch sizes, a single drill bleed down. Clamp the drill guide firmly to the pipe, orienting guide is used (CDI 5400-S-DG).