Motor Does Not Run - Miele S 8310 Descriptive Technical Documentation

Hide thumbs Also See for S 8310:
Table of Contents

Advertisement

050-4
Note
1. Super AirClean
This exhaust filter must always be changed when a new packet of Miele
dustbags is opened. Each package of Miele dustbags includes a Super Air
Clean exhaust filter.
2. Active AirClean
This exhaust filter must be changed once a year. The date of replacement
can be written directly on the filter.
3.2

Motor Does Not Run

Cause
Park switch jams after pulling out the suction hose.
Remedy
A Check the Park switch function.
A If necessary, replace the Park switch; see Park Switch Replacement (Model-
Dependent), 040 4.5.
Cause
Motor winding defective.
Remedy
A Operating Unit Removal, 040 4.1.
A Check motor winding continuity.
A If no continuity, see Motor Replacement, 050 4.2.
Note
When removing the operating unit, the plugs between the operating unit and the
motor will also be disconnected. These plugs must be lined up exactly when re-
inserting the operating unit so that they can be snapped into place.
Cause
The motor winding is too hot and the thermal protection function has tripped.
This information should not be duplicated or passed on without Miele approval. All rights reserved.
Descriptive Technical Documentation
Active HEPA
DTD no. 41-8000
07.06.2013, US_am