Installation - Foster EPro Installation And Operation Manual

Cabinets & counters with fd2-10 controller
Table of Contents

Advertisement

english
GB

installation

IMPORTANT:
To the installer: Installation of these units should be carried out by a competent person and
the appropriate codes of practice adhered to, thus ensuring safe installation.
Pass to the user: Do not discard this document as it contains important guidelines on
Operation, Loading, Cleaning and Maintenance and should be kept for reference.
DISPOSAL REQUIREMENTS
If not disposed of properly all refrigerators have components that can be harmful
to the environment. All end of life refrigerators must be disposed of by
appropriately registered and licensed waste contractors, and in accordance with
National Laws & Regulations.
Important (Cabinets only): Ensure a minimum clearance of 150mm above the unit for ventilation and
Positioning/unpacking
1
efficient operation. Where possible, ensure the unit is not adjacent to a heat source.
Cabinet
Unpacking: The unit is delivered on a pallet and shrink-wrapped. Documentation is inserted into a clear
pocket located inside the unit. Carefully remove the protective plastic film and cardboard from the
unit exterior and from the door opening surround making sure that any sharp instrument used does not cause
damage, plus remove any quality labels.
Cabinet removal from the pallet: Remove the shelf holding the package containing the castors or legs.
Remove the retaining bolts which secures the unit to the pallet. Move the unit over the front of the pallet and
fit the lockable castors or legs in the mounting holes. To fit the rear castors or legs, lock the front castors, tilt
the unit forwards, remove the pallet and fit the castors or legs in the mounting holes. Ensure that all are
tightened firmly into position.
On double door top mount cabinets, ensure 3 castors are fitted at the front.
N.B Gastro Pro 300/300 and all Fish Cabinets only. Take care not to damage the drain outlet under the base.
Counter
All cabinets are heavy and care should be taken when handling.
Counter removal from the pallet:
Counters fitted with castors - Remove fittings from inside the unit and ensure all drawers and doors are
locked before removal from the pallet. Cut the heavy duty cable ties that hold the front castors to the pallet.
Unlock the castors and then carefully roll the unit forward off the pallet.
Counters fitted with legs - Remove fittings from inside the unit and ensure all drawers and doors are
locked before removal from the pallet. Remove the fixing blocks located in front of the legs at the front of the
unit and cut the straps securing the unit to the pallet. Carefully manoeuvre the unit forward, off the pallet.
Castors
Legs
Castors/legs/feet
All models are normally fitted
2
with swivel castors. Ensure
during installation the unit is level
if not the door(s) may not close
correctly. Adjust castors by
inserting spacers under the
appropriate castor and the base
of the unit until level.
As an alternative adjustable legs
can be fitted to all models.
8mm threaded adjustable levelling
feet are available for 'U' mount
cabinet models, for all other
models 12mm threaded
Please refer to label on back
adjustable levelling feet are
and base of unit for correct
available. (Fitting method as
fitting of castors
castors or legs).
Fitting Shelves
Shelves must be inserted
4
into the unit so that they
sit at the back of the unit.
Cabinet
Counter
Units for marine
Marine Units
6
applications are provided
with special marine legs
and bulkhead fixings.
These units must be
installed by specialist
marine installation
companies.
Cabinet Bulkhead
Marine Leg
Fixings
2
Shelf/Tray Supports
To adjust the position of the
3
trayslides insert the ends into
the vertical support with the
'hooks' pointing downwards
and 'slot downwards' into
position. Ensure the
trayslides are parallel and
level after fitting.
Vaporiser Tray
This is only fitted to the Pro
5
300/300 cabinet models.
Slide the vaporiser tray onto
its runners on the underside
of the cabinet and insert the
electrical plug into the socket
provided. If the runners are
tight loosen slightly and
re-tighten after inserting the
tray. Ensure tray covers drain
outlet.
Counter Bulkhead Fixings
Geleiders & roosters (vervolg)
16
Verwijderen Geleiders
Standaard Geleiders
Verwijderen van lades
17
Gekoelde lades
Om deze lades te
verwijderen, trekt u de
lade geheel uit en tilt u
deze zó op dat de rollers
(B) door de gaatjes in de
ladegeleiders vallen.
Onthoud hierbij de
volgorde van de lades,
want als ze in een andere
volgorde worden
teruggeplaatst, kan het
gebeuren dat ze niet
goed aansluiten.
Belading
Zorg er bij de belading
Belading: goede
18
van producten voor
luchtstroom
dat de lucht kan
circuleren langs en
door de producten.
Belading: voedsel
20
Dek al het voedsel af en houd
rauw en gekookt voedsel
gescheiden. Voor verwarmde
kasten: dek het voedsel af om
uitdroging te voorkomen en
vul het reservoir voor de hoge
luchtvochtigheidsgraad op de
bodem van de kast met
water.
Probleemoplossing
Controles moeten worden uitgevoerd door een vakkundig persoon.
Probleemoplossing
21
Controleer de volgende punten, voordat u contact opneemt met de klantenservice:
a) stroomuitval (netstroom kan zijn weggevallen)
b) storingen zoals omschreven in de bedieningshandleiding voor de gebruiker: Alarmeringen en
Waarschuwingen
c) defecte zekering
Wanneer u om assistentie vraagt van de klantenservice dient u altijd de volgende gegevens bij de hand te
hebben:
a) serienummer van de machine (E..........)
b) het modelnummer aan de hand van het serienummer dat aan de binnenkant van de machine vermeld is
c) de 'foutcodereferentie', wanneer er een foutcode wordt weergegeven.
nederlands
N
Variant Visrek
Variant Verwarmd Rooster
Messenlade
(indien van
toepassing)
Deze lades zijn
vastgemaakt aan
de ladegeleiders
door middel van
afsluitclips (A).
Deze clips
moeten naar
beneden worden
geduwd om de
lade los te
maken.
Zorg voor een
19
Belading:
gelijkmatige verdeling
gewichtsverdeling
van het gewicht over het
rooster. De maximale
belasting is 40 kg per
rooster en 120 kg per
kast met enkele deur.
Plaats geen producten
40Kg
op de binnenvloer van
de kast.
23