PURPOSE OF DOCUMENT This documentation provides essential information on usage of YSoft SafeQ® Ethernet Reader. The YSoft SafeQ® Ethernet Reader is based on YSoft SafeQ® Terminal UltraLight, but is not equipped with a keyboard. VALIDITY OF DOCUMENT This document applies to YSoft SafeQ® Ethernet Reader with firmware version 1.2 and newer.
User can use also the PIN authorization (using the MFD integrated panel). The Device Server has to be confi- gured properly. Picture 1 - System Overview Only selected card readers are supported by Ethernet Reader. The YSoft SafeQ® Ethernet Reader is displayed on the Picture 2. YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 5/17...
The emergency button is used for reset the terminal into default settings. ETHERNET READER SPECIFICATION Parameter Value Identification Using a card reader Network 2-port 10/100 Mbit switch (auto MDI/MDIX) Processor Freescale Coldfire v2 Memory 64kB RAM, 512kB Flash YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 6/17...
Page 7
+5°C to +35°C Storage temperature 0°C to +50°C Working air humidity 20% to 85% without condensation Storage air humidity 8% to 85% without condensation Resistance to magnetic field no added resistance YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 7/17...
6.12.2010 TERMINAL CONFIGURATION Ethernet Reader requires TCP/IP connection to the YSoft SafeQ server. Ethernet Reader has own IP and MAC address. There is special tool for configuration of Ethernet Reader – SafeQ Terminal Configuration utils – see Picture 4. Note: This util applies to Ethernet Reader (based on YSoft SafeQ® Terminal UltraLight) with firmware version 1.2 and newer.
Page 9
SERVERIP=192.168.0.254:5011 SERVERUPD=192.168.0.254:4096 The SERVERIP corresponds to the IP address and port of the YSoft SafeQ® Device Server. The IP and port are used for card authentication. The SERVERUDP corresponds to the SafeQ server and serves for firmware updates. Emergency button is the way how to reset the terminal into default settings if anything goes wrong with the configuration.
Page 10
It is possible to enter emergency button menu by holding the button for more than 5 seconds when Ethernet Reader firmware has booted and the terminal is in default "Place card" state. YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 10/17...
After the Ethernet Reader is properly configured, it must be connected to the YSoft SafeQ®. Assume that the YSoft SafeQ® server and YSoft SafeQ® Device Server are already installed and running. Once the YSoft SafeQ® Device Server is installed and connected to the YSoft SafeQ® server, the secure queue exists in the SafeQ.
Page 12
4. Save the dialog for the queue settings. Since the serial number of the Ethernet reader is entered, both PIN (using integrated panel) and card (using Ethernet Reader) authentication are possible. YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 12/17...
The following line must be added to conf/modules/safeQ.fwupdate.conf file on the SafeQ server for the emergency update of Ethernet Reader: update-fw-ulemergency = update_file_with_ultralight_firmware Example (it is similar to Terminal Professional): update-fw-0.7.0ul = ultralight-0.8.fw YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 13/17...
This section provides flash code sequences used for interaction with a user. There are following colors used for icons: Green - Led is green Red - Led is red Orange - Led is orange YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 14/17...
Page 15
Ethernet reader model (3). Please note that ethernet reader opera- tion can be configuration selected on UltraLight or UltraLight print only models. In such case the read software configuration command can read current settings. YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 15/17...
6.12.2010 RELATIONSHIP WITH OTHER DOCUMENTS This section describes how this guide is related to other documentation: Document Version Author YSQ Ethernet Reader – User’s Guide *EN+ YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 16/17...
Public version (Reviewed and updated) Final 08/2009 Technical specification (chapter 2.2) extension – temperature Final and humidity parameters added 09/2009 Chapter 1.5 (disclaimer added) Final 12/2010 Updated version compatibility and company name Final YSOFT SAFEQ® ETHERNET READER – ADMINISTRATORS GUIDE V1.3 [EN] 17/17...