Blower/Fan (846-515)
1) Remove the two screws from the top of the
fan housing.
2) Slide the fan up into the rear heat shield.
3) After aligning holes, secure the fan to the rear
heat shield using the two screws removed
earlier.
Note: The connection cord should not be
in contact with any hot surfaces.
Read the operating instructions for the fan
before using.
Neutral
Live
120V AC
60 Hz
Fan Thermodisc
(normally open)
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug.
Green
Manual/
Ground
Auto
Switch
Black
Black
Blower/Fan Wiring Diagram
Grounding
Lug Detail
Lockwasher
Star washer
Star washer
Wire98gr.eps
updated Jan. 27/00
updated: Aug. 09/05
capitalized the word Nut
NOTE: This appliance, when installed, must
be electrically grounded in accordance
with local codes or, in the absence of local
codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical
code, CSA C22.1.
Fan
Switch
Black
Fan
CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
installation
#8 Groun Lug
d
Ground wire
Nut
from fan
Nut
Ground wire
from power cord
Fan
Ground
F1103S / F3103L
|