  • Page 1 VACON CX/CXL/CXS FREQUENCY CONVERTERS Filter Manual RFI-filters Du/dt-filters Sinus filters Subject to changes without notice. F O R S M O O T H C O N T R O L...
  • Page 2 Do not perform any high pot tests (megger) on the Vacon_SIN_B filters The Vacon_RFI_A0 filters are intended for use in earthed supplies only For unearthed (IT) supplies, contact our representative or us. Vacon Oyj Phone: +358-201-2121 Fax: +358-201-212 205 email: vacon@vacon.com...
  • Page 3 Figure 1-1 problems in the environment. The galvani- cally coupled interference may have to be Figure 1-1. The basic filtering principle of the Vacon CX_ filters. 1 = input filters, 2 = frequency converter, 3 = output filter. Type designation...
  • Page 4 EN50081 and EN 61800-3 as standard. The table below shows the filters used in order to make the Vacon CX___N range of Note that the filters 16 – 100 RFI5C2 are frequency converters comply with...
  • Page 5 Vacon Filter Manual Page 5 Figure 2 –1 Filters Vacon 16 – 100 RFI 5C2 Figure 2 –2 Filters Vacon Vacon xxx RFI 6A0 and 5A0...
  • Page 6 2.2.1 dU/dt – maker Platthaus ! In uncertain cases, confirm the rating The Vacon CX- ranges use IGBT transis- of the motor in frequency converter ap- tors as the output element. These semi- plication with the motor manufacturer.
  • Page 7 Motor current Type Weight Terminals Power loss at IVT/3.6 VACON 14 DUT 6 B 0 VACON 23 DUT 6 B 0 VACON 35 DUT 6 B 0 VACON 62 DUT 6 B 0 VACON 100 DUT 6 B 0 VACON 145 DUT 6 B 0...
  • Page 8 Motor current Type Power Terminals Weight loss at [kg] IVT/3.6 Vacon 18DUT 6B0 SH Vacon 42DUT 6B0 SH Vacon 60DUT 6B0 SH Vacon 110DUT 6B0 SH Vacon 210DUT 6B0 SH (2 x 210) Vacon 410DUT 6B0 SH (2 x...
  • Page 9 Vacon Filter Manual Page 9...
  • Page 10 Motor current Type Weight Terminals Power loss at IVT/3.6 VACON 10 SIN 6 B 0 VACON 14 SIN 6 B 0 VACON 19 SIN 6 B 0 VACON 23 SIN 6 B 0 VACON 26 SIN 6 B 0 VACON 35 SIN 6 B 0...
  • Page 11 Motor current Type Weight Terminals Power loss at IVT/3.6 VACON 4,7 SIN 5 B 0 VACON 10 SIN 5 B 0 VACON 18 SIN 5 B 0 VACON 32 SIN 5 B 0 VACON 60 SIN 5 B 0 VACON 90 SIN 5 B 0...
  • Page 12 Filter Manual Vacon /3,6kHz 2) See Figures 2-6 and 2-7. U1 U2 Figure 2-7 Main dimensions for sine filters ≥ 18 A/400V, ≥ 15 A/500 V and ≥ 14 A/690 V Vacon Oyj Phone: +358-201-2121 Fax: +358-201-212 205 email: vacon@vacon.com http://www.vacon.com...
  • Page 13 VACON OYJ PL 25 Runsorintie 7 65381 VAASA Tel: +358-201-2121 Fax: +358-201-212 205 24-hour support: +358-400-8371 150 E-mail: vacon@vacon.com http://www.vacon.com...