Page 1
V A C O N C X / C X L / C X S F R E Q U E N C Y C O N V E R T E R S I / O - e x p a n d e r b o a r d i n s t a l l a t i o n m a n u a l ( V a c o n C X S - r a n g e ) Subject to changes without notice.
I/ O - ex pa nder boa rd insta lla tion (Va con CXS- ra nge) CO N TEN TS 1 G EN ERA L .......... 2 1.1 Vacon C X1 0 0 O PT...... 2 1.2 Vacon C X1 0 1 O PT...... 2 1.3 Vacon C X1 0 2 O PT...... 2 1.4 Vacon C X1 0 3 O PT......
(Vacon CXSO PTBKIT), except the smaller, specifically for Vacon C XS designed boards (Vacon C X1 0 4 O PT , C X1 0 5 O PT , C X1 0 7 O PT , CX1 0 8 O PT).
I/ O - ex pa nder boa rd insta lla tion (Va con CXS- ra nge) 1 . 5 Va con CX1 0 4 O PT The available I/ O can be increased by using the Vacon CX1 0 4 O PT I/ O -expander board: - encoder input T ypical use: Closed L oop Vector Control 1 .
I/ O 's may have a dangerous voltage connected even if the power is disconnected from the frequency converter. Vacon Plc T el: +358-201 2121 Fax: +358-201 212 205 Service: +358-40-8371 150 E-mail: vacon@vacon.com http:/ / w w w.vacon.com...
Before doing any commissioning, carefully read the safety instructions in the "USER'S M AN UAL , V ACO N CX/ CXL / CXS", Chapter 1 , SAFETY . Disconnect the frequency converter from the mains. N O TE: Also the control circuits! W ait further 5 minutes before opening the cover of the frequency converter.
T able 3 -2 . I/ O -expander board installation (continues ...). Vacon Plc T el: +358-201 2121 Fax: +358-201 212 205 Service: +358-40-8371 150 E-mail: vacon@vacon.com http:/ / w w w.vacon.com...
Page 8
1 ,5 cm), tighten up to the metal clamp (of the cable) and earth the cable to the frequency converter ground as shown in the picture. T able 3 -2 . I/ O -expander board installation (continues ...). Vacon Plc T el: +358-201 2121 Fax: +358-201 212 205 Service: +358-40-8371 150 E-mail: vacon@vacon.com http:/ / w w w.vacon.com...
Page 9
Install the jumper removed from the control board X4 terminal into the I/ O -expander board terminal X9 . N ote: the jumper can be connected in O N or O FF position,see Vacon CX/ CXL/ CXS User's manual, Chapter 6 .2 .2 .
Page 10
Before connecting the mains make sure that the cover of the option box and frequency con- verter are closed. Set the parameters of I/ O -expander board according to the Vacon "Five in O ne+" -applica- tion manual (parameter group 3 ).
Page 11
I/ O -expander box can also be installed beside the frequency converter (unit sizes M 3 , M 4 B and M 5 B). Vacon Plc T el: +358-201 2121 Fax: +358-201 212 205 Service: +358-40-8371 150 E-mail: vacon@vacon.com http:/ / w w w.vacon.com...
FAUL T R O5/ 2 Figure 4 -1 Control connections of Vacon CX1 0 0 O PT . * ) N O TE! Thermistor input (terminals 2 2 1 and 2 2 2 ) must be shorted if not used.
R UN R O4/ 2 Figure 4 -2 Control connections of Vacon CX1 0 1 O PT . * ) N O TE! Thermistor input (terminals 2 2 1 and 2 2 2 ) must be shorted if not used.
FAUL T R O5/ 2 Figure 4 -3 Control connections of Vacon CX1 0 2 O PT . * ) N O TE! Thermistor input (terminals 2 2 1 and 2 2 2 ) must be shorted if not used.
Relay output 5 FAULT R O5/ 2 Figure 4 -4 Control connections of Vacon CX1 0 3 O PT . * ) N O TE! Thermistor input (terminals 2 2 1 and 2 2 2 ) must be shorted if not used.
4 . 5 Va con CX1 0 4 O PT M ore information on the Vacon CX1 0 4 O PT encoder option board you will find in a separate manual (ud3 1 8 ). Ask your distributor for more information.
Need help?
Do you have a question about the CX and is the answer not in the manual?
Questions and answers