Installation Quickstart
– continued
Step
3
Route the AC power conduit to the rear or bottom (as appropriate) AC I/O panel on the cabinet and
terminate conduit.
4
Route the 208–240 VAC power wires from the power meter breaker box, through the AC power
conduit, through the I/O boot, to the AC load center.
5
Connect the AC wires to the appropriate terminals (see Chapter 5 for details).
C

Heat Dissipation

144
Table C-7: AC Power Cabling Procedures
*
SC
4812ET RF and Power Cabinet Hardware Installation Manual
TM
Action
IMPORTANT
The minimum heat dissipated to prevent condensation
inside the cabinet under the extremes of environmental
conditions is 110 Watts for the RF Cabinet and 110 Watts
for the Power Cabinet. This can be accomplished by
following the Initial Power Up procedures in the SC
4812ET ATP manual.
DRAFT
Apr 2001
V0C.03