Powerplant Instrument Markings; Systems Limitations; Weight Limits - Piper Archer III PA-28-181 Handbook

With garmin g1000 system
Table of Contents

Advertisement

SECTION 2
LIMITATIONS

2.9 POwERPLANT INSTRUMENT MARKINGS

(a) Tachometer
Green Arc (Normal Operating Range)
Red Line (Maximum)
(b) Oil Temperature
Green Band (Normal Operating Range)
Red Line (Maximum)
(c) Oil Pressure
Green Band (Normal Operating Range)
Yellow Band (Caution Range) (Idle)
Yellow Band (Ground Warm-Up)
Red Line (Minimum)
Red Line (Maximum)

2.11 SYSTEMS LIMITATIONS

(a) Emergency Battery
Minimum

2.13 wEIGHT LIMITS

(a) Maximum Ramp (lbs.)
(b) Maximum Weight (lbs.)
(c) Maximum Baggage (lbs.)
REPORT: VB-2749
2-4
PA-28-181, ARCHER III
500 to 2700 RPM
55 PSI to 95 PSI
25 PSI to 55 PSI
95 PSI to 115 PSI
23.3 VOLTS
Normal
2558
2550
200
ISSUED: December 22, 2017
2700 RPM
75° to 245°F
245°F
25 PSI
115 PSI
Utility
2138
2130
0