7.33 STALL WARNING

An approaching stall is indicated by a stall warning aural alert which is
activated between five and ten knots above stall speed. Mild airframe buffeting
and gentle pitching may also precede the stall. Stall speeds are shown on the
Stall Speed graph in Section 5. The stall warning aural alert is activated by a lift
detector on the leading edge of the left wing. Whenever the stall warning system
is activated, a STALL...STALL aural alert is heard through the cockpit speaker
and through the headsets. During preflight, the stall warning system should be
check by turning the BATT MSTR switch on, lifting the detector and check to
determine if the system is active.

7.35 FINISH

All exterior surfaces are primed with etching primer and finished with a
polyurethane finish.

7.37 EXTERNAL POWER

An external power installation is accessible through a receptacle located
on the right side of the fuselage aft of the wing. An external battery can be
connected to the socket, thus allowing the operator to crank the engine without
having to gain access to the airplane's battery.

7.39 EMERGENCY LOCATOR TRANSMITTER

The Emergency Locator Transmitter (ELT), is located in the aft portion of
the fuselage just below the stabilator leading edge and is accessible through a
plate on the right side of the fuselage. This plate is attached with slotted-head
nylon screws for ease of removal; these screws may be readily removed with a
variety of common items such as a dime, a key, a knife blade, etc. If there are
no tools available in an emergency the screw heads may be broken off by any
means.
A battery replacement date is marked on the transmitter. To comply with
FAA regulations, the battery must be replaced on or before this date. The
battery must also be replaced if the transmitter has been used in an emergency
situation or if the accumulated test time exceeds one hour, or if the unit has been
inadvertently activated for an undetermined time period.