2A
Number of Bedrooms
Sq Ft
1
2
3
500
20
28
35
600
21
29
36
700
22
30
37
800
23
31
38
900
24
32
39
1000
25
33
40
1100
26
34
41
1200
27
35
42
1300
28
36
43
1400
29
37
44
1500
30
38
45
1600
31
39
46
1700
32
40
47
1800
33
41
48
1900
34
42
49
2000
35
43
50
2100
36
44
51
2200
37
45
52
2300
38
46
53
2400
39
47
54
2500
40
48
55
2600
41
49
56
2700
42
50
57
2800
43
51
58
2900
44
52
59
3000
45
53
60
3100
46
54
61
3200
47
55
62
3300
48
56
63
3400
49
57
64
3500
50
58
65
Table 2A: Continuous Ventilation Rate in CFM
per ASHRAE 62.2-2010 Standard
4
5
6
43
50
58
44
51
59
45
52
60
46
53
61
47
54
62
48
55
63
49
56
64
50
57
65
51
58
66
52
59
67
53
60
68
54
61
69
55
62
70
56
63
71
57
64
72
58
65
73
59
66
74
60
67
75
61
68
76
62
69
77
63
70
78
64
71
79
65
72
80
66
73
81
67
74
82
68
75
83
69
76
84
70
77
85
71
78
86
72
79
87
73
80
88
Continuous Calculation
Page 7 of 36
2B
Number of Bedrooms
Sq Ft
1
2
3
500
30
38
45
600
33
41
48
700
36
44
51
800
39
47
54
900
42
50
57
1000
45
53
60
1100
48
56
63
1200
51
59
66
1300
54
62
69
1400
57
65
72
1500
60
68
75
1600
63
71
78
1700
66
74
81
1800
69
77
84
1900
72
80
87
2000
75
83
90
2100
78
86
93
2200
81
89
96
2300
84
92
99
2400
87
95
102
2500
90
98
105
2600
93
101
108
2700
96
104
111
2800
99
107
114
2900
102
110
117
3000
105
113
120
3100
108
116
123
3200
111
119
126
3300
114
122
129
3400
117
125
132
3500
120
128
135
Table 2B: Continuous Ventilation Rate in CFM
per ASHRAE 62.2-2013/2016 Standard
4
5
6
53
60
68
56
63
71
59
66
74
62
69
77
65
72
80
68
75
83
71
78
86
74
81
89
77
84
92
80
87
95
83
90
98
86
93
101
89
96
104
92
99
107
95
102
110
98
105
113
101
108
116
104
111
119
107
114
122
110
117
125
113
120
128
116
123
131
119
126
134
122
129
137
125
132
140
128
135
143
131
138
146
134
141
149
137
144
152
140
147
155
143
150
158