Siemens RWF50 Application Manual page 7

Rwf5 series modulating feeswater control valve

Advertisement

Parameters
SP1
SP2
Opr
dSP
lnP1
Y
Pb1
dt
rt
db
tt
Controlling element running time
HYS1
PArA
HYS2
Switch-off threshold (stage II)
HYS3
HYS4
HYS5
Switch-off threshold (stage II)
HYS6
q
SEn1
Analog input 1 sensor type
OFF1
Analog input 1 correction (offset)
SCL1
Analog input 1 scale low level
lnP
InP1
SCH1
Analog input 1 scale high level
dF1
Analog input 1 filter time constant
Unit
CtYP
CACt
Cntr
SPL
SPH
oLLo
Lower working range limit
oLHi
Upper working range limit
FnCt
rAFC
rASL
toLP
rAL
FnCt
ConF
SiGn
Analog output signal type
0utP
r0ut
Value when input is out of range
0Pnt
End
bin1
binF
diSU
diSL
diSP
tout
dECP
CodE
RWF50 Menu Options
Parameter Name
Setpoint 1
Setpoint 2
Setpoint shift
Analog input 1
Angular positioning
Proportional band
Derivative time
Integral time
Dead band
Switch-on threshold
Switch-off threshold
Switch-on threshold
Switch-off threshold
Response threshold
Temperature units
Controller type
Operating action
Setpoint low limit
Setpoint high limit
Thermal shock function
Ramp slope
Tolerance band ramp
Ramp limit value
Analog output function
Re-transmit scale low
Re-transmit scale high
Binary input 1 function
Upper display
Lower display
Timeout
Decimal places
Locking of levels
Factory
Your
Value Range
Setting
Setting
SPL...SPH
60
SPL...SPH
0
SPL...SPH
0
N/A
-
N/A
-
1...9999
10
0...9999 sec
80
0...9999 sec
350
0.0...999.9
1
10...3000 sec
15
-1999...0.0
-5
0.0...HYS3
3
0.0...9999
5
0.0...9999
5
HYS6...0.0
-3
-1999...0.0
-5
0.0...999.9
0
1...19 →
1
-1999...9999
0
-1999...9999
0
-1999...9999
100
0.0...100.0 sec
0.6
1, 2
1
1, 2
N/A
0, 1
1
-1999...9999
0
-1999...9999
100
-1999...9999
-1999
-1999...9999
9999
0, 1, 2
0
0.0...999.9
0
2*|HYS1|...9999
0
0...250
0
0, 1, 4
4
0, 1, 2
0
0...101 %
0
-1999...9999
0
-1999...9999
100
0, 1, 2, 4
0
0, 1, 4, 6, 7
1
0, 1, 4, 6, 7
6
0...255 sec
180
0, 1, 2
0
0, 1, 2, 3
0
Notes
Only if bin1 = 1
Only if bin1 = 2
Cannot be edited here (just a display)
Cannot be edited here (just a display)
RWF 50.2 only
RWF 50.2 only
Only if CACt = 1
Only if CACt = 1
Only if CACt = 1
Only if CACt = 0
Only if CACt = 0
Only if CACt = 0
1 = Pt-100 3-wire, 2 = Pt100 2-wire,
3 = Pt1000 3-wire, 4 = Pt1000 2-wire,
5 = Ni1000 3-wire, 6 = Ni1000 2-wire,
7 = 0-135 Ohm, 15 = 0-20 mA, 16 = 4-20 mA,
17 = DC 0-10 V,18 = DC 0-5 V, 19 = DC 1-5 V
1 = Celsius, 2 = Fahrenheit
1 = 3-position (50.2 only),
2 = modulating (50.3 only)
0 = cooling controller, 1 = heating controller
0 = disconnected, 1 = Kelvin/min,
2 = Kelvin/hour
Only appears if FnCt ≠ 0
Only appears if FnCt ≠ 0
Only appears if FnCt ≠ 0
0 = no function, 1 = analog input 1,
4 = controller angular position
0 = 0-20 mA, 1 = 4-20 mA, 2 = DC 0-10 V
Output percentage
Only if FnCt = 1
Only if FnCt = 1
0 = no function, 1 = setpoint changeover,
2 = setpoint shift,
4 = operating mode changeover
0 = disconnected, 1 = analog input 1,
4 = controller angular position, 6 = setpoint,
7 = thermal shock end value
0 = disconnected, 1 = analog input 1,
4 = controller angular position, 6 = setpoint,
7 = thermal shock end value
0 = no decimal place, 1 = one decimal,
2 = two decimals
0 = no lockout, 1 = configuration level,
2 = parameter and configuration level,
3 = keyboard lockout
Page
Number
34
40
28
42
43
44
45
46
47

Advertisement

loading

This manual is also suitable for:

Rwf55