Example

:CONTinuous?

Example

[:IMMediate]

Comments
Example
Chapter 5
Enabling Continuous Scans
INIT:CONT ON
SCAN (@100:115)
INIT
INITiate:CONTinuous?
scanning enabled, the command returns 1 (ON). With continuous scanning
disabled, the command returns 0 (OFF).
Query Continuous Scanning State
INIT:CONT ON
INIT:CONT?
INITiate[:IMMediate]
in the channel list. Successive triggers from the source specified by the
TRIGger:SOURce
Starting the Scanning Cycle: The
starts scanning by closing the first channel in the channel list. Each
trigger received advances the scan to the next channel in the channel
list. An invalid channel list generates an error (see the
[ROUTe:]SCAN
Stopping Scanning Cycles: See the
Enabling a Single Scan
SCAN (@100:115)
INIT
HP E1351A/53A 16-Channel FET Multiplexer Command Reference
queries the scanning state. With continuous
starts the scanning cycle and closes the first channel
command advances the scan through the channel list.
command).
Enables continuous scanning.
Sets channel list.
Starts scanning cycle.
Enables continuous scanning.
Query continuous scanning state.
INITiate[:IMMediate]
command
command.
ABORt
Sets channel list.
Starts scanning cycle.
61