Welch Allyn 5002 Directions For Use Manual

Welch Allyn 5002 Directions For Use Manual

Masted scales
Hide thumbs Also See for 5002:

Advertisement

Welch Allyn Masted Scales
Directions for use
Models 5002, 5122, 5702, 6002

Advertisement

Table of Contents
loading

Summary of Contents for Welch Allyn 5002

  • Page 1 Welch Allyn Masted Scales Directions for use Models 5002, 5122, 5702, 6002...
  • Page 2 © 2016 Welch Allyn. All rights are reserved. To support the intended use of the product described in this publication, the purchaser of the product is permitted to copy this publication, for internal distribution only, from the media provided by Welch Allyn. No other use, reproduction, or distribution of this publication, or any part of it, is permitted without written permission from Welch Allyn.
  • Page 3: Table Of Contents

    About warnings and cautions ................2 Controls and indicators ..................3 Assembly and setup ................7 Models 5002 and 5702 stand-on scales .............. 7 Model 5122 stand-on scale .................. 8 Model 6002 wheelchair scale ................8 Custom setup ...................... 8 Scale operation ..................
  • Page 4 Contents Welch Allyn Masted Scales...
  • Page 5: Introduction

    The Welch Allyn Masted Scales are intended to be used by clinicians for weighing patients up to 660 pounds (300 kg) for model 5122, up to 880 pounds (400 kg) for models 5002 and 6002, and up to 1000 pounds (454 kg) for model 5702. Indications for use The Welch Allyn Masted Scales are used by clinicians to weigh patients.
  • Page 6: About Warnings And Cautions

    Caution statements can appear on the Welch Allyn Masted Scales, the packaging, the shipping container, or in this Directions for use. The Welch Allyn Masted Scales are safe for patients and clinicians when used in accordance with the instructions and caution statements presented in this Directions for use.
  • Page 7: Controls And Indicators

    Make sure you record the measurement units as they are displayed. CAUTION Do not use this scale to transport patients or items. Controls and indicators Scale Models 5002 and 5702 Steering handle/hand grip Front panel Mast Hand rail...
  • Page 8 4 Introduction Welch Allyn Masted Scales Wheels Weighing platform N/A Battery access door (located on the rear of the mast) N/A Height gauge (optional) Model 6002 Steering handle/hand grip Control panel Mast Hand rail (optional) Wheels Weighing platform Wheelchair ramp...
  • Page 9 Directions for use Introduction 5 Model 5122 Control panel Mast (battery access door located on front) Weighing platform...
  • Page 10 6 Introduction Welch Allyn Masted Scales Front panel buttons Button Function ZERO Press this button to reset the scale to zero. Press this button to turn on the scale. Press this button in conjunction with to enter the setup mode.
  • Page 11: Assembly And Setup

    When special tools are required, they are supplied with the scale. Ensure that all bolts and fasteners are securely tightened. Use the following instructions to assemble and setup your scale for use. Models 5002 and 5702 stand-on scales 1. Carefully remove all parts from the shipping carton and inspect the components for shipping damage.
  • Page 12: Model 5122 Stand-On Scale

    Model 5122 stand-on scale The 5122 model scale is shipped assembled, so no assembly is required. It operates the same as the 5002 model. Handrails are not available for this scale. Model 6002 wheelchair scale 1. Carefully remove all parts from the shipping carton and inspect the components for shipping damage.
  • Page 13 RECALL This option allows you to turn button functionality. rS-232 Detailed instructions for this feature are available from Welch Allyn. Go to http:// www.welchallyn.com/en/other/contact-us.html to find your local representative. OutPut* This option displays the current data port output option. Detailed instructions for this feature are available from Welch Allyn.
  • Page 14 10 Assembly and setup Welch Allyn Masted Scales If the pounds indicator is illuminated, it will only print in pounds, regardless of the unit is selected on the control panel. PrtOPT* RECALL Press to choose between the following options: PnlPrt...
  • Page 15: Scale Operation

    Scale operation Power options The scale can be used with battery power or with AC power. Battery power CAUTION Use only size D disposable alkaline batteries. The use of any other battery will void the warranty. Press ON to turn on the scale. The scale automatically turns off after 45 seconds of non-use when operating on battery power.
  • Page 16: Weighing Procedure

    12 Scale operation Welch Allyn Masted Scales Four long The battery is too weak to operate the scale. beeps Four short The scale has entered setup mode. beeps Weighing procedure 1. Press ON to turn on the scale. The scale sounds one beep.
  • Page 17: Print A Weight Measurement

    Directions for use Scale operation 13 A stationary display of - - indicates a negative weight. Make sure that there is nothing on the scale and press ZERO to set the zero. If O-LOAd displays, the capacity of the scale has been exceeded. If OFF SCALE PLEASE –...
  • Page 18 14 Scale operation Welch Allyn Masted Scales...
  • Page 19: Storage, Cleaning, And Maintenance

    Storage, cleaning, and maintenance Storage The scale should be stored in a convenient storage facility or closet. Make sure to not leave the scale in an area where someone could trip on it or run into it. Cleaning 1. Clean the scale at least once per day, and the optional handrail after each use. 2.
  • Page 20: Change The Printer Paper

    16 Storage, cleaning, and maintenance Welch Allyn Masted Scales Change the printer paper The printer is a purchasable option. 1. Use a screwdriver to loosen the screw on the battery access door and remove the printer access door. 2. Remove the spindle containing the empty printer paper roll from the printer paper well.
  • Page 21: Maintenance

    Directions for use Storage, cleaning, and maintenance 17 8. Install the printer access door, and advance the new paper through the slot on the door. 9. Install the screw on the printer access door. Maintenance Routinely perform the following preventive maintenance to keep your scale in working order.
  • Page 22 18 Storage, cleaning, and maintenance Welch Allyn Masted Scales Issue Possible cause Suggested action The scale buttons are not The buttons may be damaged Check for visible signs of responding damage. Contact your service department. E-FAIL The scale's memory has failed Contact your service department.
  • Page 23: Appendices

    Nominal output current: I : 1000mA Platform dimensions 5002: 18 in. x 19.5 in. x 1.5 in. 5702: 24 in. x 26 in. x 2 in. 6002: 24 in. x 26 in. x 2 in. 5122: 16 in. x 14 in. x 1.5 in.
  • Page 24: Product Configurations

    20 Appendices Welch Allyn Masted Scales Product configurations The Welch Allyn Masted Scales are available in the following configurations: Model 5002, Mobile Stand-On Scale Model Description 5002-KP Mobile Stand-On Scale, kilogram only, printer 5002-KX Mobile Stand-On Scale, kilogram only, data port...
  • Page 25: Approved Accessories

    Directions for use Appendices 21 Approved accessories Model 5002 Part number Description 845010 Height gauge (in and cm) 845010M Height gauge (metric only) 845010W Wall-mounted height gauge (in and cm) 50231 Printer 23709 Thermal printer paper (box, 15 rolls) 845233...
  • Page 26: Warranty

    UL/CSA power adapter with hospital-grade plug Warranty Welch Allyn will warranty the weight scale to be free of defects in material and workmanship and to perform in accordance with manufacturer specifications for the period of one year from the date of retail purchase.
  • Page 28 Material No. 725556...

This manual is also suitable for:

57026002512267026702sp6702w