Kitett MINIKIT SOLO Instructions For Use Manual

Hide thumbs Also See for MINIKIT SOLO:

Advertisement

Quick Links

Contents
MINIKIT SOLO
by
GB - INSTRUCTIONS FOR USE
ES - INSTRUCCIONES DE USO
PT - MANUAL DE UTILIZAÇÃO
GR - ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ
NO - BRUKSANVISNING
FI - KÄYTTÖOHJE
.......................................................................................................
...................................................................................................
...............................................................................................
.............................................................................................................................................
....................................................................................................................
...........................................................................................................................................
p.5
p.31
p.57
p.83
p.109
p.135
GB
ES
PT
GR
NO
FI

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINIKIT SOLO and is the answer not in the manual?

Questions and answers

Summary of Contents for Kitett MINIKIT SOLO

  • Page 1 Contents MINIKIT SOLO GB - INSTRUCTIONS FOR USE ....................... p.31 ES - INSTRUCCIONES DE USO ....................p.57 PT - MANUAL DE UTILIZAÇÃO ....................p.83 GR - ΟΔΗΓΙΕΣ ΧΡΗΣΗΣ ............................. p.109 NO - BRUKSANVISNING ........................p.135 FI - KÄYTTÖOHJE ............................
  • Page 2: Table Of Contents

    Operating instructions for Minikit Solo 1. Intended Use 6. Maintenance p.18 Indications External cleaning Contraindications and of the breast pump p.18 adverse effects Cleaning the protective membrane p.18 2. Product description 7. Safety precautions Detailed view and description p.19 Selection of the breast shield size p.9 8.
  • Page 3: Intended Use

    The MINIKIT SOLO breast pump is a personal electric pump. It can be used in case of temporary separation or any other reason making breastfeeding impossible or There are many reasons why women express their milk: not sufficient.
  • Page 4: Detailed View And Description

    Detailed view and b. Selecting the breast shield size description ➊ The MINIKIT SOLO breast pump is used with the KIT EXPRESSION KOLOR . A breast ® Kolor ® Breast shield shield is included in the MINIKIT SOLO standard Breast Pump package.
  • Page 5: Accessories

    KOLOR ® breast shields are guaranteed BPA and Phthalate free. Cleaning They are reusable for as long as the breast pump is used. The breast shield is a one-piece which favors an optimized hygiene, and makes it possible not to touch the thread nor the and disinfecting accessories internal parts of the feeding collection container and the breast shield.
  • Page 6: Use

    LR6 1.5V alkaline batteries. Insert them according to the diagrams indicated in the with fingers in the breast shield. box. Close the compartment before switching on the appliance. • The battery-operated MINIKIT SOLO breast pump has an operation range of ➌ Screw the KITETT Kolor breast shield with the valve onto the ®...
  • Page 7: Using The Breast Pump

    ➍ At any time in the expression cycle, you can press the 5 setting The MINIKIT SOLO breast pump operates with button to go back to the lower setting level. levels that are gradually displayed on the right and left corner of the display screen.
  • Page 8: After Each Use

    Rinse, leave to air dry on a paper towel. b. Physiology of baby breastfeeding The MINIKIT SOLO Breast Pump provides mothers with the natural sensation of breastfeeding by recreating the way in which babies feed. It reproduces the 2 physiological phases of the breastfeeding: - The stimulation phase to generate the milk let-down (short, rapid movements), - The expression phase to collect milk (longer, less frequent movements).
  • Page 9: Maintenance

    Maintenance Safety precautions a. External cleaning of the breast pump Use of electricity Cleaning is confined to external parts. • Before connecting the appliance to an electrical outlet, check the values in the Disinfection is done with a clean, damp cloth. operating instructions of the appliance (volts and Hz) and your distribution network.
  • Page 10: Troubleshooting

    • If you find that the device is noisy or malfunctioning, contact your supplier. Troubleshooting • Fragile medical device, to be handled with care. • No special knowledge or training is required to operate this equipment. • Keep these instructions in a safe place with the appliance as it contains the necessary Problem Solution information for the proper use of the equipment.
  • Page 11: List Of Accessories/ Spare Parts Available

    Collection container stand - Batch of 2 ex. YSUPBIB WB26EL – WB30ES/WB30EL Pouch - Batch of 2 ex. Y1423 The MINIKIT SOLO breast pump is compatible with KOLOR ® autoclavable breast MINIKIT SOLO protective membrane - 1 ex. Y20278 shields.
  • Page 12: Warranty/Recycling

    Absorbed power 3,0 W Suction Values 50 to 300 mbar ± 10% Kitett breast pumps must be disposed of in accordance with local Rate 50 to 120 cycles/min disposal guidelines for electrical appliances. Use your local waste disposal system for electrical and electronic equipment (including batteries). You Noise <...
  • Page 13: Electromagnetic Compatibility (Emc)

    12 inches (30 12: Operator code; 2017: year; 26: week of manufacture. cm) to any part of the MINIKIT SOLO breast pump, including cables specified by the manufacturer. Otherwise, performance may be impaired.
  • Page 14 Pictograms Guidance and manufacturer’s declaration - electromagnetic immunity Test level Immunity test Compliance Level IEC 60601 Symbols featured ± 8 kV through direct ± 8 kV Electrostatic discharge (ESD) Compliance with Directive 93/42/EEC of 14 June 1993 relating to contact IEC 61000-4-2 ±...
  • Page 15: Pictograms

    Instrucciones de uso para Minikit Solo This symbol indicates the moisture limit which must not be excee- ded in the case of operation, transport, and storage. This symbol indicates the limit of atmospheric pressure not to be exceeded during operation, transport or storage.