Quick Links

Important: Read the 2 Cylinder
Mobile Cart User's Manual /
Instructions FM-1346 & applicable
Nitrous Oxide and Oxygen Delivery
System User's Manual, which
includes these topics:
 Warnings and Precautions
 Delivery Technique
 Safety Checks
 Maintenance and
Troubleshooting
 Proper Use of Cylinders
 Connection to Flow Devices
Use FM-1345 Assembly Instructions
Examination of Contents
Examine shipping carton for signs of
external damage.
Remove contents from carton and
inspect for visible damage or missing
components. See page 2 for
complete list.
If damage is discovered or suspected
and/or parts are missing, notify
Porter or authorized distributor
immediately.
PORTER CUSTOMER SERVICE: 215-723-4000
www.porterinstrument.com
2 CYLINDER MOBILE CART
USER'S MANUAL / INSTRUCTIONS
Parker Hannifin Corporation
Precision Fluidics Division
Porter Instrument
245 Township Line Road
Hatfield, PA 19440
Office 215-723-4000/Fax 215-723-5106
www.PorterInstrument.com
2 Cylinder Mobile Cart shown with Nitronox System.
Cylinders not included.
Medical Breathing Circuit, Nitronox, & Scavenger
System sold separately.
FM-1346 Rev. – 1/2017

Advertisement

loading
Need help?

Need help?

Do you have a question about the Porter Nitronox and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker Porter Nitronox

  • Page 1 Parker Hannifin Corporation Precision Fluidics Division Porter Instrument 245 Township Line Road Hatfield, PA 19440 Office 215-723-4000/Fax 215-723-5106 www.PorterInstrument.com 2 CYLINDER MOBILE CART USER’S MANUAL / INSTRUCTIONS Important: Read the 2 Cylinder Mobile Cart User’s Manual / Instructions FM-1346 & applicable Nitrous Oxide and Oxygen Delivery System User’s Manual, which...
  • Page 2 2 CYLINDER MOBILE CART COMPONENTS Component Component Item Image Item Image Description Description Mounting Wheel Base Adapter Hex Screw Pole Hardware Washer End Cap w/ 3 Kit * Lock Washer Screws Wrench Handle w/ 2 12 Hex Nut Adapter Screws N2O Hose (Blue) (included w/ Pole...
  • Page 4 Warnings and Precautions These warnings and precautions are to help you to understand how to safely operate a 2-Cylinder Mobile Cart with a nitrous oxide & oxygen delivery System. A WARNING alerts you to a possible hazard to people. A CAUTION alerts you to the possibility of equipment damage. WARNING: Protect against crossed lines at the 2 Cylinder Mobile Cart regulator assembly.
  • Page 5: Intended Use

    WARNING: External gas supplies may range from 40 to 65 psi line pressure. Follow safe connection protocol in this order: Connect external gas supply hoses to DISS (Diameter Indexed Safety System) fittings of Flowmeter or Nitronox (O2 first); then connect to external supply source.
  • Page 6 WARNING: Protect against crossed lines at the 2 Cylinder Mobile 4. Check the “LP” (low pressure) & “HP” (high Cart regulator assembly. Verify gas indexing pressure) label engravings near the fitting pin locations, color coding of gauges, seal connections on the back of the regulators. The “HP”...
  • Page 7 Attachment of Flowmeters or Nitronox Matrx D-MDM Matrx MDM Porter MXR 3000 Nitronox The 2 Cylinder Mobile Cart allows attachment of various Porter devices, illustrated above for the Matrx D-MDM, Matrx MDM, Porter MXR 3000, and Nitronox. 1. For all device attachments to the Cart Pole, use the Mobile Cart Mounting Adapter (Item 10) and Hex Nut Adapter (Item 12) screwed into the device mounting feature (See Fig.
  • Page 8 Proper Attachment of Gas Cylinders Caution: When removing cylinders, always Fig. 8 be sure valves are closed tightly. 1. Cylinder Preparation: Remove any plastic wrap/washer from the top of cylinder. 2. Lock casters. Facing from the back of Mobile Cart, place cylinders into angled Cylinder Holders, allowing bottom of cylinders to rest on bottom of Holders (Fig.
  • Page 9 5. Label cylinders with a tag or sticker indicating “In- Cylinder Operation / Maintenance Use” and “Full” (“Full” is reserve), if appropriate. Cylinder Pressure Readings: Oxygen is a true compressed gas, while in the cylinder, thus the 6. Use Cylinder Wrench to open the “In-Use” cylinder pressure gauge can be used to determine the cylinders.
  • Page 10 Attachment of Medical Breathing Circuit Scavenger System The Scavenger Interface attaches to the pole of the Mobile Cart, with the bottom of the Interface nesting between the two Cylinder Holders and the top behind the Utility Basket. Note: If location dimensions of the Utility Basket and Cylinder Holder were not strictly followed (see FM- 1345 2-Cylinder Mobile Cart Assembly Instructions), the Scavenger Interface may not fit properly with...
  • Page 11: Certificate Of Warranty

    Parker Hannifin Corporation. Parker Hannifin Corporation shall not be liable for any damage, injury or loss arising out of the use of the product, whether as a result of a defect in the product or otherwise, if, prior to such damage, injury or loss, the product was (1) damaged or misused;...