This LCD Auto Range Digital AC (True RMS)/DC clamp
multimeter is a portable, 6000digits multimeter. It is ideally suited
for field, laboratory, shop and home applications.
1. SAFETY INFORMATION
The following safety information must be observed to insure
maximum personal safety during the operation at this meter.
1) When measuring voltage ensure that instrument is not
switched to the current range, resistance range, diode and
continuity range, capacitance range or temperature range.
2) Use extreme care when measuring voltage above 50V.
especially from sources where high energy is existed.
3) Avoid making connections to "live" circuits whenever possible.
4) Before making resistance measurements, diode or continuity
test, capacitance test or temperature test, ensure that the circuit
under test is de-energized.
5) Always ensure that the correct function and range is selected.
6) Extreme care should be taken when using the instrument to
conjunction with a current transformer connected to the terminals
if an open circuit occurs.
7) Ensure that the test leads and probes are in good condition
with no damage to the insulation.
8) Take care not to exceed the over-load limits as given in the
specifications.
9) Before opening the cover of the battery cabinet to replace
batteries. disconnect the test leads from any external circuit, set
the selector switch to "OFF" position.
10) Keep the fingers after the protection ring when measuring
through the instrument lead.
1) Change the battery when the symbol "
1
incorrect data
2.Panel Layout
1)Rotary Switch: use this switch to select functions and ranges.
2)SELECT key: This key work on the "Ω
key to choose resistance, diode ,continuity test. And on the
current range, change to DC/AC.
3)Hz/Duty key:In Voltage or current range, push the key, you
can measure the Hz ,push again, can measure the duty.
4)HOLD light switch :Pressing this button the present display
value will be locked and the " H " symbol will appear, push it
again to exit HOLD and the " H"symbol disappear.
5)REL switch :Pressing this button, the meter enters relative
measuring mode
6) LCD Display
7)T- Input Jack、COM Input Jack、V Ω /T+Input Jack .
8)Photo sensor: The photo sensor can reaction to the ambient
brightness range, then automatically control the LCD
backlight to lighten or go out.
9)The NCV light
3. SPECIFICATIONS
3.1 GENERAL SPECIFICATIONS
Display: 3 3/4 digit LCD with a max. reading of 3999.
Range control: Auto range control.
Polarity: Automatic negative polarity indication.
Zero adjustment: Automalic.
Over range indication: Only the "OL" display.
Low battery: The "
" is display when the battery voltage is below 2.2V
Safety Standards: The meter is up to the standards of IEC1010
Double Insulation, Pollution
Degree 2, Over voltage Category Ⅲ.
Clamp opening size: 34mm.
Operating Environment: Temperature 32~104°F(0~40℃),
humidity<80%RH.
Storage Environment: Temperature -4~140°F(-20~
60℃),humidity<90%RH.
Power supply: 3 x 1.5V AAA batteries.
Dimension: 193(H) x 73(W) x 26(D) mm
Weight: Approx.325 g (including battery)
3.2 ELECTRICAL SPECIFICATIONS
Accuracies are ±(% of reading +number in last digit)
at 23±5℃,≤70%RH.
3.2.1 DC Voltage
Range
600mV
600V
Overload protection: 600V DC/600Vrms AC
Impedance: 10MΩ,More than 100MΩ on 400mV scale
3.2.2 AC Voltage (True RMS)
Range
600mV
60V
600V
Average sensing, calibrated to rms of sine wave
Overload protection: 600V DC/600Vrms AC
Impedance: 10MΩ.
3.2.3 DC Current
Range
60A
600A
Overload protection: 600Arms within 60 seconds
3.2.4 AC Current (True RMS)
Range
" appears to avoid
Average sensing, calibrated to rms of sine wave
Overload protection: 600Arms within 60 seconds
3.2.5 Resistance
Range
600kΩ
60MΩ
Overload protection: 250V DC/250Vrms AC
3.2.6 Capacitance
Range
9.999nF
99.99nF
999.9nF
" range , Push the
9.999μF
99.99μF
999.9μF
9.999mF
99.99mF
Overload protection: 250V DC/250Vrms AC
3.2.7 Frequency
Range
9.999Hz
99.99Hz
999.9Hz
9.999kHz
99.99kHz
100kHz
Duty Range: 1%~99% Accuracy 0.2%
Overload protection: 250V DC/250Vrms AC
3.2.8 Temperature(NiCr-NiSi sensor)
Range
Overload protection: 250V DC/250Vrms AC
3.2.9 Diode and Audible continuity test
Range
Accuracy
0.8% of rdg+5digits
6V
60V
0.5% of rdg+5 digits
Accuracy
1.5% of rdg+5digits
6V
1.0% of rdg+5 digits
1.5% of rdg+5digits
Accuracy
2.5% of rdg+8 digits
Accuracy
60A
2.5% of rdg+8 digits
600A
Accuracy
600Ω
1% of rdg+8 digits
6kΩ
60kΩ
1% of rdg+5 digits
6MΩ
2.0% of rdg+5 digits
Accuracy
3.0% of rdg+10 digits
2.5% of rdg+5 digits
5.0% of rdg+10 digits
10% of rdg+20 digits
Accuracy
0.5% of rdg+5digits
Accuracy
-20~1000℃
2.5% of rdg+3 digits
-4~1832℉
2.5% of rdg+6 digits
Description
Display read approx.
Forward voltage of diode.
Built-in
buzzer
sounds
resistance is less than 50Ω
Resolution
0.1mV
1mV
10mV
100mV
Resolution Frequency
0.1mV
50~100Hz
1mV
10mV
50~400Hz
100mV
Resolution
Frequency
0.01A
0.1A
Resolution
Frequency
0.01A
50~60Hz
0.1A
Resolution
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
10pF
100pF
1nF
10nF
100nF
1uF
10uF
Resolution
Sensitivity
0.001Hz
0.01Hz
0.1Hz
≥7V/ rms
1Hz
10Hz
100 Hz
Resolution
1℃
1℉
Test condition
Forward DC current
approx. 1.0mA
Reversed DC voltage
approx. 3.0V
if
Open circuit voltage
aprox. 1.0V

Advertisement

loading
Need help?

Need help?

Do you have a question about the 6208 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HoldPeak 6208

  • Page 1 HOLDPEAK 3.2 ELECTRICAL SPECIFICATIONS Accuracies are ±(% of reading +number in last digit) 6208 at 23±5℃,≤70%RH. OPERATION MANUAL 3.2.1 DC Voltage This LCD Auto Range Digital AC (True RMS)/DC clamp Range Accuracy Resolution multimeter is a portable, 6000digits multimeter. It is ideally suited 600mV 0.8% of rdg+5digits...
  • Page 2 Overload protection: 250V DC/250Vrms AC 4) Read the result from the LCD panel. 4. MEASURING INSTRUCTION Max.input over-load: 250V rms<10sec 4.1 Voltage measurement A. The temperature function shows the ambient temperature when did not insert the thermocouple. 1) Connect the black test lead to "COM" socket and red test lead B.