Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate
or maintain the product described. Protect yourself and others by observing all safety information. The Safety Instructions are contained in the General Operating
Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions
for future reference. AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.
©2015 AMT Pump Company, A Subsidiary of The Gorman-Rupp Company, All Rights Reserved.
Periodic maintenance and inspection is required on all pumps to ensure proper operation. Unit must be clear of debris and sediment. Inspect for leaks and loose bolts. Failure to do so
voids warranty.
Bronze Marine Pump
Refer to pump manual 1808-634-00 for General Operating and Safety Instructions.
DESCRIPTION
This non self-priming, low pressure, centrifugal pump is intended for liquid transfer, re-circulation and wash down applications in marine environments where no
suction lift is required. Pump is sized for saltwater (1.03 specific gravity) and features provisions for the installation of an automatic seal wash. This may extend
shaft seal life by retarding salt crystallization on seal wear face. Seal wash hose not included. For use with nonflammable, non-abrasive liquids compatible with
pump component materials. Units are equipped with a TEFC (Totally Enclosed Fan Cooled), ball bearing, splash protected, capacitor start, 4 pole motor. Thermal
protection not provided. The motor has ON/OFF switch, standard plug and six foot cord.

INSTALLATION

Because of crystallization and erosive material on shaft seal (Ref. No. 11),
installation of a seal wash is recommended to avoid premature leaks. Two
types may be used, a recirculated liquid type or a clean liquid type. Sometimes
a periodic seal cleaning is unavoidable.
Use pipe or hose to connect drain port on front of casing (Ref. No. 15) to seal
flush port on side of adapter (Ref. No. 9). Whenever pump is running, this re-
circulation line will flush seal.
Or, connect a line supplying clean liquid to seal flush port on adapter. Always
use an in-line check valve on this line. Flush as required.

MAINTENANCE

Disconnect from power source before servicing or inspecting the pump
for any reason. Failure to do so could result in fatal electrical shock!

MECHANICAL SEAL REPLACEMENT

Refer to Figures 1, 2 and 3.
IMPORTANT: Always replace both the seal seat and the seal head (Ref. No.
11) to ensure proper matching of components!
1.
Unthread cap screws (Ref. No. 2) and remove casing (Ref. No. 15) and
o-ring (Ref. No. 14).
2.
Unscrew impeller (Ref. No. 13) from shaft (Ref. No. 7). To keep the shaft
from turning, remove three screws holding the motor fan guard and
remove the guard. Loosen the screw clamping the fan to the motor shaft
and remove the fan. When the fan is removed, the shaft can be held using
vise grip pliers or other suitable means.
3.
Remove the three hex nuts (Ref. No. 8) and remove the adapter (Ref.
No. 9).
4.
Lay the adapter face down on a flat stable surface and press the seal
cartridge from the adapter.
5.
Pry the seal seat from the rear of the impeller with a screwdriver or other
suitable means.
3670-253-00
Figure 1 - Mechanical Seal Replacement
6.
Clean the recess in the adapter for the seal cartridge and the recess in the
impeller for the seal seat before inserting any new parts.
7.
Inspect the ceramic face of the seal seat and carbon face of the cartridge
to insure they are clean and not marred.
Figure 2 - Mechanical Seal Replacement
1
3670-94
4/2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3670-94 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AMT 3670-94

  • Page 1 Instructions. Failure to comply with the safety instructions accompanying this product could result in personal injury and/or property damage! Retain instructions for future reference. AMT reserves the right to discontinue any model or change specifications at any time without incurring any obligation.
  • Page 2 3670-94 Specifications Information and Repair Parts Manual Bronze Marine Pump Press the new cartridge into the recess in the adapter. A sealing compound SHIM ADJUSTMENT (such as silicon or Permatex) may be used to assure a water tight fit on the outside of the cartridge.
  • Page 3 3670-94 Specifications Information and Repair Parts Manual Bronze Marine Pump For Repair Parts contact dealer where pump was purchased. Please provide following information: -Model Number -Serial Number (if any) Part description and number as shown in parts list Figure 3 - Repair Parts Illustrations...

Table of Contents