Gas Clip Technologies Single Gas Clip User Manual

Hide thumbs Also See for Single Gas Clip:

Advertisement

Quick Links

Single Gas Clip and SGC Plus
User's Manual Rev 2.06

READ BEFORE OPERATION

Gas Clip Technologies (GCT) Single Gas Clip and
SGC Plus detectors are personal safety devices
designed to detect the presence of specific toxic
gases (Carbon Monoxide (CO) or Hydrogen Sulfide
(H2S)) or Oxygen (O2) deficiency. Accordingly please
ensure you have been properly trained on the use of
the equipment and appropriate actions in the event of
an alarm condition.
WARNING
If the detector is past the "Activate Before
Date" on the package, please do not activate.
Do not attempt part replacement or
substitution as this could impair the intrinsic
safety rating and will void the warranty of the
product.
Before daily use check the following:
-Sensor and Audio ports are clear of any
obstructions i.e. debris or blockage
-Perform the "Self-test" to ensure proper
operation of visual, audible, and vibrating
-Confirm receipt of a check mark in the
upper left hand corner signaling a successful
"Self-test"
Calibrate the O2 detector at least every 30
days. Make sure to calibrate in a clean air
environment. See O2 detector section for
instructions on calibration.
Both the CO and H2S versions of the Single
Gas Clip and SGC Plus do not require
calibration for the life of the product, however
we do recommend bump tests please see
our bump test recommendations below:
Bump Test the detector periodically by
challenging the sensor with a known
concentration of the target gas to be
detected. Recommended target gas
concentrations (H2S: 25 ppm, CO: 200
ppm, O2: 18%). Bump Test can be
performed either manually or through the
SGC Dock. If a manual test is to be
performed make sure to test in a clean air
environment.
If a detector fails the Self-test or Bump Test
please discontinue use.
The detector contains a lithium battery that
must be disposed of by a qualified recycler.
Single Gas Clip and SGC Plus User's Manual Rev 2.06
Do not substitute internal components as this
may interfere with the intrinsic safety of the
device.
Do not attempt to replace the battery or
sensor, this product is designed to be
disposable. Changing these components will
void the warranty.
If you suspect any malfunction or have any
technical problems please contact GCT at
877-525-0808

Activating the Detector

To activate the detector, press and hold down button for
approximately 5 seconds. Upon activation, the detector will
vibrate, flash, and sound the audible alarm. A successful
activation will display the life remaining in months on the
detector as 24 months.

Display Details

The detector utilizes a special high viewing angle LCD that is
designed to enhance the screen visibility. In the absence of
gas, it displays life remaining. In those cases where gas is
present, the display will automatically shift to a display that
shows gas concentration and a battery icon.
*Note the display mode can be changed in the IR Link
software with the "Sensor Reading" and "Life Remaining"
user options.
Warning: Users must familiarize themselves with
the icons in both non-alarm and alarm states
Warning: If the display is missing icons or cannot
be clearly read, please contact GCT immediately
Single Gas Clip and SGC Plus User's Manual Rev 2.06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Single Gas Clip and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gas Clip Technologies Single Gas Clip

  • Page 1 If a detector fails the Self-test or Bump Test please discontinue use. The detector contains a lithium battery that must be disposed of by a qualified recycler. Single Gas Clip and SGC Plus User’s Manual Rev 2.06 Single Gas Clip and SGC Plus User’s Manual Rev 2.06...
  • Page 2 “Bump Test Interval” for more detail. I f the detector is displaying “EOL” it has reached the end of its operating life. Please discontinue use. Single Gas Clip and SGC Plus User’s Manual Rev 2.06 Single Gas Clip and SGC Plus User’s Manual Rev 2.06...
  • Page 3 Confirm these levels with your company safety officer. DO NOT use IR communications when an explosive atmosphere may be present. Single Gas Clip and SGC Plus User’s Manual Rev 2.06 Single Gas Clip and SGC Plus User’s Manual Rev 2.06...
  • Page 4 The sensor screen may be cleaned with a soft brush under clean, warm water. Return the filter to the detector once it has fully dried. Single Gas Clip and SGC Plus User’s Manual Rev 2.06 Single Gas Clip and SGC Plus User’s Manual Rev 2.06...
  • Page 5 Single Gas Clip and SGC Plus User’s Manual Rev 2.06 Single Gas Clip and SGC Plus User’s Manual Rev 2.06...
  • Page 6 Cedar Hill, TX 75104 date of activation for all Single Gas Clip products and the Toll Free: +1 (877) 525-0808 SGC Plus monitor for 3 years from date of activation or 24 Phone: +1 (972) 775-7577 months of operational life, whichever occurs first.

This manual is also suitable for:

Sgc plus

Table of Contents