Autotrol 460i Operation And Maintenance Manual page 7

Electronic control system
Table of Contents

Advertisement

Problem
8. Continuous
regeneration. Camshaft
does not stop at the end
of regeneration.
9. Control will not
regenerate
automatically or when
button is pressed.
10. Control will not
regenerate
automatically but will
regenerate when button
is pressed.
11. Run out of soft water
between regenerations.
Note 1: The use of resin cleaners in an unvented enclosure is
not recommended.
Cause
a. Broken switch activator on gear.
b. Defective switch.
a. Electric cord unplugged.
b. No electric power at outlet.
c. Defective motor.
d. Broken gear.
e. Binding in gear train.
f.
Defective switch.
a. If water flow display is not
operative, refer to Item 5.
b. Defective circuit board.
c. Incorrect hardness and capacity
settings.
a. Improper regeneration.
b. Fouled softener resin.
c. Incorrect salt setting.
d. Incorrect hardness or capacity
settings.
e. Water hardness has increased.
f.
Restricted meter turbine rotation
due to foreign material in meter
housing.
g. Excessive water usage below
1/5 gallon per minute.
7
Solution
a. Replace timer.
b. Replace timer.
a. Connect power.
b. Repair outlet or use working outlet.
c. Replace timer.
d. Replace timer.
e. Replace timer.
f.
Replace timer.
a. Same as Item 5.
b. Replace timer.
c. Set to correct values. See
Programming section.
a. Repeat regeneration, making certain
that correct salt dosage is used.
b. Use resin cleaner. See Note 1.
c. Set salt control to proper level. See Salt
Setting chart.
d. Set to correct values. See
Programming section.
e. Set hardness to new value. See
Programming section.
f.
Remove meter housing, free up turbine
and flush with clean water. DO NOT
DISASSEMBLE TURBINE FROM
METER HOUSING. Turbine should spin
freely; if not, replace meter
g. Repair leaky plumbing and/or
!
fixtures
!