Autotrol 460i Operation And Maintenance Manual

Electronic control system

Advertisement

460i
The 460i Electronic Control System
Operation and Maintenance Manual

Advertisement

Table of Contents
loading

Summary of Contents for Autotrol 460i

  • Page 1 460i The 460i Electronic Control System Operation and Maintenance Manual...
  • Page 2: 460I Electronic Demand System

    Low or No Water Usage determines if the water conditioner has enough The 460i is programmed to recognize a day of very little remaining capacity to supply the next day’s needs. If or no water usage as an abnormality. It will not use data not, the unit will regenerate.
  • Page 3: Programming The 460I

    Programming the 460i hardness range is from 1 to 99 grains per gallon. To change water hardness stated in parts per million Plug the wall mount transformer into a functioning (PPM) to grains per gallon (GPG), use this formula. electrical outlet that is not controlled by a switch. Plug...
  • Page 4: Adjustment Of Brine Control

    Hardness and Capacity Settings If power fails during a conditioner regeneration, the cycle will be completed normally when the power is Once the hardness and capacity settings have been restored. set, the information cannot be lost due to a power outage;...
  • Page 5 Table 1 - Suggested Salt Dial Settings (Pounds of Salt) for Various Size Softeners Resin Bed Volume Capacity Setting .5 ft .75 ft 1.0 ft 1.25 ft 1.5 ft 1.75 ft 2.0 ft 2.5 ft Kilograins 18.5 12.5 11.5* 10.5* 10.5* *This setting requires use of “XS”...
  • Page 6: Troubleshooting

    Troubleshooting Your water conditioning system is designed and IMPORTANT: Service procedures that require the manufactured for efficient, low maintenance service. water pressure to be removed from the system are However, if problems do occur, this section provides a marked with a !. To remove water pressure from the list of possible causes and solutions.
  • Page 7 Problem Cause Solution 8. Continuous a. Broken switch activator on gear. a. Replace timer. regeneration. Camshaft b. Defective switch. b. Replace timer. does not stop at the end of regeneration. 9. Control will not a. Electric cord unplugged. a. Connect power. regenerate b.
  • Page 8: Disinfection Of Water Conditioners

    Disinfection of Water Conditioners 1. Dosage a. Polystyrene resin; 1.2 fluid ounce per cubic The materials of construction of the modern water foot. conditioner will not support bacterial growth nor will b. Non-resinous exchanger; 0.8 fluid ounce per these materials contaminate a water supply. However, cubic foot.