DESCRIPTION
L models description: self-powered 12 Vdc sounder with high-brightness low-consumption LED flashing unit - double reed
tamper against sounder opening and against any attempts of removing the sounder from the wall – programmable sounds and
timings – alarm counting – optical and acoustic signaling of System ON/OFF (arming/disarming) - electronic circuit protected
against polarity inversion and tropicalized by resin immersion – microprocessor self-check of recharge, battery and speaker –
flash reset input – internal cover made of 10/10 zinc-plated steel (Aluzinc system) – outside cover made of painted ABS or 10/10
zinc-plated steel (Aluzinc system) or shiny stainless steel according to the model chosen.
LS models description: technical features as per L models, with patented double micro anti-foam anti-shock device against hard
hits (patent no. 00238576).
MA-SE-RTL0-03-01 Manuale Rialto Triade Lido Eng rev1
Page 1 of 8

Advertisement

loading

Summary of Contents for Venitem RIALTO L

  • Page 1 INSTALLATION MANUAL SOUNDER MODELS RIALTO L – LS – X – LSX TRIADE L – LS – QL – QLS LIDO L – X – LS – LSX DESCRIPTION L models description: self-powered 12 Vdc sounder with high-brightness low-consumption LED flashing unit - double reed tamper against sounder opening and against any attempts of removing the sounder from the wall –...
  • Page 2: Connection Scheme

    CONNECTION SCHEME A) CONNECTION USING THREE WIRES. Connect 13.8 Volt power supply coming from the control panel to the corresponding terminals: -RIC negative; +RIC positive; +C positive-missing trigger. NOTE: DIP-SWITCH no. 2 is set by the manufacturer in OFF position, POSITIVE-MISSING TRIGGER. CONTROL PANEL GND 0V +13.8V...
  • Page 3 DIP 3 in ON position  Giving a negative (0V) to terminal no. 5, all LEDs of the flashing unit flash 3 times (ON). Anomalies are reset to zero.  Taking away the negative, all LEDs stay lighted up steady for 5 seconds (OFF) and the complete sounder test is launched. In case of anomalies, they are duly notified.
  • Page 4 SETTING Anomaly output. Open-collector at 0V = no anomaly Chart 2: ALARM TIMING DIP 1 Alarm timing OFF (default setting) 3 minutes 8 minutes Chart 4: ALARM INPUT POLARITY OF SOUNDER COMMAND, TERMINAL no. 3 DIP 2 Terminal 3 OFF (default setting) Positive-missing (alarm if disconnected or 0V) Negative-missing (alarm if disconnected or +12V) Chart 5: ALARM SYSTEM ON/OFF NOTICE, TERMINAL no.
  • Page 5 INSTALLATION/MAINTENANCE ADVICES: In case the sounder does not work properly, verify if the LED located on the main board is flashing. If it flashes, check the ANOMALY NOTICE CHART above. MOUNTING: Screw the sounder on the wall and check if the tamper works properly; Insert the connection cables through the holes localed on the sounder base;...
  • Page 6: Technical Features

    All Venitem products are granted against factory or material defects. In order to improve design and quality of the products, Venitem reserves the right to modify the products without prior notice. All faulty or defective products must be returned to the supplier.
  • Page 7 NOTE MA-SE-RTL0-03-01 Manuale Rialto Triade Lido Eng rev1 Page 7 of 8...
  • Page 8 Via del Lavoro, 10 - 30030 Salzano (VE) Tel. (39) 041 5740374 – Fax (+39) 041 5740388 Web site www.venitem.com E-mail info@venitem.com MA-SE-RTL0-03-01 Manuale Rialto Triade Lido Eng rev1 Page 8 of 8...

This manual is also suitable for:

Rialto lsxRialto lsRialto xTriade lTriade lsTriade ql ... Show all