7. For solid walls drill the fixing holes for the
backplate with a 6 mm drill and insert the
wall plugs (supplied). For other types of wall
structure alternative fixings may be required
(not supplied).
8. Drill the holes for the supply pipes and fit the
supply pipework:
hot to bottom Inlet, cold to top Inlet
Note! the inlet pipework should extend
between 12 and 18 mm from the finished wall
surface.
Caution! make sure that the pipework is not
damaged otherwise the olives will not seal.
9. fit the backplate over the inlet pipes and
secure to the wall using the fixing screws
(supplied).
Note! make sure that the backplate is the
correct way up (refer to illustration).
10. Caution! It is essential at this point
that the supply pipework is thoroughly
flushed through before connection to the
mixer. failure to do so may result in product
malfunction and will not be covered under the
guarantee.
11. fit the olives onto the inlet pipework and tighten
the inlet nuts using a suitable spanner.
Caution! do not overtighten.
Important! Make sure that the inlet filters are
fitted in the inlet nuts as illustrated.
Cold Inlet
Hot Inlet
large boss must be
fitted at the bottom
fixing screws
Inlet nut
olive
filter
12. make sure that the concealing plate (with
the hole at the bottom) is loosely fitted over
the mixing valve inlets and align the mixer
with the inlet nuts. Push on fully and tighten
the grubscrews to secure the mixer to the
backplate. make sure that the grubscrews are
engaged fully in the valve body grooves.
13. Push the concealing plate onto the backplate,
secure with the m4 x 12 mm grubscrew.
single grubscrew secures
the top inlet to the backplate
two grubscrews securing both the
bottom inlet and the concealing
plate to the backplate.