ITEM
OSW Camera Window (on the
camera enclosure)

Weekly Maintenance

ITEM
Vacuum System
Reject Solenoid Valve
Diffuser Glass
Infeed and Outfeed Bottle Guides
Takeaway System
Starwheel Suction Cups
Light Source Lens
OSW Light Source
Industrial Dynamics Company, Ltd. © Form 42600 (10/03)
DAILY MAINTENANCE
Check for scratches or other damage. Clean with a
NONCAUSTIC, NONABRASIVE commercially available
glass cleaner (such as Windex).
WEEKLY MAINTENANCE
Check efficiency of system by seating bottles firmly in all
pockets with pressure/vacuum converter running. Vacuum
Gauge on panel should read at least 22 inches Hg. If gauge reads
less, check suction cups and be sure bottles are seated firmly. If
reading still low, check piping for leaks and refer to Monthly
Maintenance Checklist for more details.
Cycle manually by pressing small button on body of valve.
Check for proper slip when the glass disk is stopped. The glass
disk should run true and not bind against adjacent components.
Check for cracks, deep scratches, etc. Clean thoroughly.
Check alignment and tighten all knobs securely. Bottles should
have approximately 3 mm (1/8 inch) clearance on each side as
they pass through guides. Guides should merge smoothly with
conveyor guide rails and give a smooth bottle transition into the
starwheel. Check and replace plastic wear inserts as necessary.
Lubricate the grease fittings located on the side of the Reject
Conveyor channel. Any good grade of bearing grease may be
used.
Check for cracks, and replace if necessary. Check for bent
vacuum tubes (caused when pipes are not aligned to starwheel).
Replace and align vacuum tubes if necessary.
Clean top surface thoroughly. DO NOT REMOVE THE
LENS.
Check that the fluorescent lighting units are functioning
properly.
Chapter 1: Periodic Maintenance
1-3